MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

  • MOQQuote on request
  • Lead timeUsually 1–7 days
  • WarehouseYantai / Hong Kong
Request a quote

Product Details

Yantai Boxin International Trading Co., Ltd. is a professional comprehensive trading service provider for communication equipment.With warehouses established in Yantai and Hong Kong, we have built a complete and localized network for delivering communication products and services.In 2018, Yantai Boxin International Trading Co., Ltd. set up its international sales department in Yantai, China.Based in China, we operate in emerging markets across Southeast Asia, India, the Middle East, Africa, Europe, and the United States. 

Yantai Boxin International Trading Co., Ltd. supplies products to various telecom operators, meeting their needs for supplementing and expanding 2G/3G/4G/5G network stations.Our current equipment portfolio covers brands such as Nokia, Ericsson, Alcatel, Huawei, ZTE, ZTT, and FiberHome. 

We expand our international market share by offering high-quality products, excellent service, competitive pricing, and timely delivery.Feel free to contact us for more information.

Product Description

1.Product Overview

1.Basic information of the board

Attribute specification description

OptiX OSN 9800 series intelligent optical transmission platform

Board name: 8-channel optical add/drop multiplexing board (DWDM)

Function positioning realizes the on/off and multiplexing functions of 8 consecutive wavelength channels in DWDM system

Type of board: Passive Optical Add/Drop Multiplexing Board (OADM)

Compatible with subracks such as OSN 9800 U series/M series that support TN series cards

Front panel dimensions: height x width x depth: 264.6 mm x 25.4 mm x 220 mm

Weight 1.0 kg

Typical power consumption 0.3 W

Maximum power consumption of 0.4 W (normal operation at maximum ambient temperature)

Working temperature -5°C to+55°C

Key features include 8-channel continuous uplink and downlink, DWDM support, passive design with zero power consumption, multiple fixed wavelength configurations, cascaded expansion interfaces, and wavelength query function

2.Interface and Port Definition

Interface Identification Interface Type Quantity Function Description

IN LC/UPC 1 line input port, receiving multiplexed signals from fiber optic lines

OUT LC/UPC 1 line output port, sending multiplexed signals to fiber optic lines

D1~D8 LC/UPC 8 downstream ports, which separate the specified 8 consecutive wavelengths from the multiplexed signal to the local receiver

A1~A8 LC/UPC 8 uplink ports, insert 8 consecutive wavelengths from the local transmitter into the multiplexed signal

MI/MO LC/UPC 2 cascade interface, used to connect another OADM board for channel expansion

3.Core functional characteristics

Functional Module Technical Description System Value

Wavelength uplink and downlink enable the uplink and downlink functions of 8 consecutive DWDM wavelength channels, while other wavelengths can be directly routed locally or inserted with specific wavelength services without the need for complete wavelength splitting, saving costs

Fixed wavelength grouping supports multiple consecutive 8-channel configurations, covering the main frequency range of the C-band and providing standardized wavelength combination selection, simplifying network planning and configuration

Cascade expansion capability provides MI/MO cascade interface, which can be connected to another OADM board to achieve channel expansion.It supports smooth expansion from 8 channels to 16/24/32 channels, adapting to network expansion needs

The wavelength query function supports querying the configuration information of upstream and downstream wavelengths, making it easy for operation and maintenance personnel to grasp the current channel configuration status

The DWDM standard supports compliance with DWDM technical specifications, with a channel spacing of 100GHz, fully compatible with mainstream DWDM systems, and suitable for backbone and metropolitan wavelength division networks

Does the optical layer ASON support -

Passive design is mainly based on passive optical devices to achieve functions, with a power consumption of only 0.3W, ultra-high reliability, zero heat generation, and long service life, without the need for additional heat dissipation

4.Example of wavelength grouping

The TN11MR8 board supports up and down channels of 8 consecutive channels, typically providing multiple predefined wavelength combinations.The following is an example grouping (using ITU-T 100GHz grid and C-band as an example):

Group number feature code channel range (THz) center frequency (A1~A8)

1     19210-19280        192.10 ~ 192.80   192.10, 192.20, 192.30, 192.40, 192.50, 192.60, 192.70, 192.80

2     19290-19360        192.90 ~ 193.60   192.90, 193.00, 193.10, 193.20, 193.30, 193.40, 193.50, 193.60

3     19370-19440        193.70 ~ 194.40   193.70, 193.80, 193.90, 194.00, 194.10, 194.20, 194.30, 194.40

4     19450-19520        194.50 ~ 195.20   194.50, 194.60, 194.70, 194.80, 194.90, 195.00, 195.10, 195.20

5     19530-19600        195.30 ~ 196.00   195.30, 195.40, 195.50, 195.60, 195.70, 195.80, 195.90, 196.00

Note: The actual grouping may vary slightly depending on the hardware version, and the specific coding confirmed at the time of ordering shall prevail.

5.Optical performance parameters

Parameter Port/Channel Specification Remarks

The working wavelength range is 1529 nm -1561 nm for all ports in the C-band, which complies with the DWDM standard

Adjacent channel spacing -100 GHz DWDM standard channel spacing

-1dB spectral width IN-D1~D8 ≥ 0.2 nm downstream channel bandwidth

-1dB spectral width A1~A8-OUT ≥ 0.2 nm uplink channel bandwidth

The insertion loss of the downstream channel IN-D1~D8 ≤ 2.5 dB is the loss from the line downstream to the local receiver

On road channel insertion loss A1~A8-OUT ≤ 2.5 dB Loss from local transmitter on the road to the line

Direct channel insertion loss IN-MO/MI-OUT ≤ 1.8 dB Direct loss without upstream and downstream wavelengths

Isolation between adjacent channels with downstream ports>25 dB suppresses crosstalk between adjacent channels

Non adjacent channel isolation provides higher isolation when the downstream port is greater than 35 dB

Direct channel isolation IN-MO/MI-OUT>13 dB Direct channel inter isolation

Maximum reflectivity -40 dB for all ports with excellent return loss characteristics, reducing reflection

6.Power consumption and mechanical parameters

Parameter specifications

Typical power consumption 0.3 W

Maximum power consumption 0.4 W

Front panel dimensions 264.6 mm (height) x 25.4 mm (width) x 220 mm (depth)

Weight 1.0 kg

Working temperature -5°C to+55°C

Storage temperature -40°C to+70°C

7.Comparison with OADM boards of the same series

Characteristics TN11MR2 TN11MR4 TN11MR8

Number of channels 2 channels (arbitrary) 4 channels (continuous) 8 channels (continuous)

Up and down rules: Any 2 channels randomly configured, fixed, continuous 4 channels grouped, fixed, continuous 8 channels grouped

Up and down path insertion loss ≤ 1.5 dB ≤ 2.2 dB ≤ 2.5 dB

Direct insertion loss ≤ 1.0 dB ≤ 1.5 dB ≤ 1.8 dB

Optical layer ASON supports or does not support

Working wavelength range: C-band, C-band, C-band

Typical power consumption 0.2 W 0.2 W 0.3 W

Applicable scenarios require flexible up and down nodes with random wavelength configuration, fixed 4 wavelength planning nodes, high-density fixed 8 wavelength up and down nodes

8.Application scenarios

Core Value of Application Scenario Deployment Method

The DWDM metropolitan core aggregation node is deployed at the middle node of the metropolitan core ring to achieve flexible up and down of 8-channel wavelength level local services at low cost, avoiding the construction of large terminal stations

The interconnection of regional data centers is located at the exit of the regional data center, providing high-density and low-cost DCI interconnection wavelength up and down solutions for 8 wavelengths to local devices

The intermediate communication station of the trunk line is located at the intermediate station of the long-distance trunk line.A continuous set of 8 wavelengths is sent to the local business network to save the wavelength resources of the trunk line and simplify the station configuration

Expanding fixed OADM nodes as fixed OADM nodes, combined with MR4/MR2 and other technologies, to build a flexible network with hybrid uplink and downlink capabilities that meet the requirements of different wavelength quantities

Cascaded expansion networking uses MI/MO interfaces to cascade multiple MR8 boards, constructing 16/24/32 channel OADM nodes that support smooth expansion of channel numbers to meet business growth needs

9.Maintenance and ordering information

Project Information

Component code TN11MR8 (specific version such as TN11MR8-XXX represents specific wavelength grouping)

Ordering instructions: When placing an order, it is necessary to confirm the wavelength grouping requirements.MR8 supports multiple sets of continuous 8-wavelength fixed configurations

On site operation supports hot plugging, and anti-static wrist straps should be worn during operation.Pay attention to cleaning the fiber optic connectors

Wavelength configuration does not require on-site configuration.According to the wavelength grouping at the time of ordering, the board has been fixed to correspond to 8 consecutive wavelength channels

If the cascade connection needs to expand the number of channels, it is necessary to correctly connect the MI/MO cascade ports to ensure the correct direction of the optical path

After testing and verifying installation, insertion loss testing, upper and lower channel connectivity testing, and cascading function verification are required

Spare parts management, as a passive component, has high reliability, but critical nodes can be configured with spare parts for quick recovery

Core Summary:

TN11MR8 is an 8-channel DWDM optical add/drop multiplexing board in the OSN 9800 platform.Based on passive optical device design, it realizes the on/off and multiplexing functions of 8 consecutive wavelength channels in the DWDM system.

Core values and positioning:

High density wavelength uplink and downlink solution: Provides 8-channel continuous wavelength uplink and downlink capabilities to meet the needs of medium scale wavelength aggregation/add/drop, making it an efficient choice for fixed OADM nodes.

Standardized wavelength grouping: supports multiple predefined continuous 8-wavelength configurations, covering the main frequency range of the C-band, simplifying network planning and configuration, and reducing engineering complexity.

Cascade expansion capability: Through the MI/MO cascade interface, multiple MR8 boards can be connected to achieve smooth expansion of channel numbers, adapting to the progressive expansion needs of the network from 8 channels to 16/24/32 channels.

Zero power consumption and high reliability: Based on passive optical device design, with a power consumption of only 0.3W, it has extremely high reliability and long service life, without the need for heat dissipation considerations.

Comprehensive operation and maintenance support: Supports wavelength query function, making it easy for operation and maintenance personnel to grasp the current channel configuration status.

Technical features:

8-channel continuous up and down capability, supporting multiple fixed wavelength configurations

Working wavelength range 1529-1561nm (C-band), channel spacing 100GHz

Up and down path insertion loss ≤ 2.5dB, direct insertion loss ≤ 1.8dB

Adjacent channel isolation>25dB, non-adjacent>35dB

Provide MI/MO cascade interface, supporting multi board cascade expansion

Passive design, power consumption only 0.3W, zero heat generation

Application suggestion:

This board is an 8-channel OADM component for DWDM core/aggregation layer in OSN 9800 wavelength division system, which is particularly suitable for scenarios that require fixed wavelength planning and continuous 8-channel uplink and downlink, such as intermediate nodes in urban core rings, interconnection of regional data centers, and intermediate communication stations in trunk lines. For scenarios that require more channels, smooth expansion can be achieved by cascading multiple MR8 boards. In conjunction with the iMaster NCE intelligent control system, unified management and operation of the core layer optical network can be achieved. For flexible nodes that require random wavelength configuration or optical layer ASON support, TN11MR2 is a more suitable choice.

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDMMR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

Overview

Product Description

 

Product 
100% original refurbishment.
Condition
REF
Size
50*50*15cm
Delivery date
Lead time 2 days

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

Packing & Shipping

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

Company Introduction

 

We can provide sales of a large number of new or used transmission equipment, servers, communication power systems, routers, base station equipment, switches, SFPs, storage devices, and other communication products.We have extensive knowledge and experience in product operation and maintenance.We have multiple professional technical personnel to provide testing for our products, ensuring that every refurbished spare part is perfect.It can reduce costs for your network maintenance.Looking forward to working with you.

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDMMR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

MR8: 8-channel Optical Add/drop Multiplexing Unit TN11MR8 ---OptiX OSN9800 WDM

 

 

 

 

 

Contact Us

Yantai Boxin International Trade Co., Ltd.

Huijiang · Sales

WhatsApp / WeChat / Phone

+86 185 5406 5950

[email protected]

Anna · Sales

WhatsApp / WeChat / Phone

+86 186 6382 8268

[email protected]

Click the number to chat on WhatsApp or send an email. WeChat ID is the same as the phone number.