Yantai Boxin International Trading Co., Ltd. is a professional comprehensive trading service provider for communication equipment.With warehouses established in Yantai and Hong Kong, we have built a complete and localized network for delivering communication products and services.In 2018, Yantai Boxin International Trading Co., Ltd. set up its international sales department in Yantai, China.Based in China, we operate in emerging markets across Southeast Asia, India, the Middle East, Africa, Europe, and the United States.
Yantai Boxin International Trading Co., Ltd. supplies products to various telecom operators, meeting their needs for supplementing and expanding 2G/3G/4G/5G network stations.Our current equipment portfolio covers brands such as Nokia, Ericsson, Alcatel, Huawei, ZTE, ZTT, and FiberHome.
We expand our international market share by offering high-quality products, excellent service, competitive pricing, and timely delivery.Feel free to contact us for more information.

|
Technical Specifications
|
S12704
|
S12708
|
S12710
|
S12712
|
|
Height [mm]
|
441.7 mm
|
663.9 mm
|
663.9 mm
|
841.75 mm
|
|
Depth [mm]
|
585 mm
|
585 mm
|
585 mm
|
585 mm
|
|
Width [mm]
|
442 mm
|
442 mm
|
442 mm
|
442 mm
|
|
Chassis height [U]
|
10
|
15
|
15
|
19
|
|
Weight without packaging
|
24.5 kg (54.01 lb)
|
42 kg (92.59 lb)
|
28.6 kg (63.05 lb)
|
64 kg (141.09 lb)
|
|
Maximum power consumption [W]
|
2550
|
5234
|
4644
|
6790
|
|
Heat dissipation mode
|
Absorb air
|
Absorb air
|
Absorb air
|
Absorb air
|
|
Maximum heat dissipation [BTU/h]
|
8700.855
|
17858.9314
|
15845.7924
|
23168.159
|
|
Input voltage range [V]
|
DC input: -40 V DC to -72 V DC
AC input: 90 V AC to 290 V AC; 47 Hz to 63 Hz (When the input voltage ranges from 90 V AC to 175 V AC, the maximum output power of the power module is halved.) High-voltage DC input (3000 W AC power module): 190 V DC to 290 V DC |
DC input: -40 V DC to -72 V DC
AC input: 90 V AC to 290 V AC; 47 Hz to 63 Hz (When the input voltage ranges from 90 V AC to 175 V AC, the maximum output power of the power module is halved.) High-voltage DC input (3000 W AC power module): 190 V DC to 290 V DC |
DC input: -40 V DC to -72 V DC
AC input: 90 V AC to 290 V AC; 47 Hz to 63 Hz (When the input voltage ranges from 90 V AC to 175 V AC, the maximum output power of the power module is halved.) High-voltage DC input (3000 W AC power module): 190 V DC to 290 V DC |
DC input: -40 V DC to -72 V DC
AC input: 90 V AC to 290 V AC; 47 Hz to 63 Hz (When the input voltage ranges from 90 V AC to 175 V AC, the maximum output power of the power module is halved.) High-voltage DC input (3000 W AC power module): 190 V DC to 290 V DC |
|
Rated input voltage [V]
|
DC input: –48 V DC or –60 V DC
AC input: 110 V AC/220 V AC, 50/60 Hz High-voltage DC input (3000 W AC power module): 240 V DC |
DC input: –48 V DC or –60 V DC
AC input: 110 V AC/220 V AC, 50/60 Hz High-voltage DC input (3000 W AC power module): 240 V DC |
DC input: –48 V DC or –60 V DC
AC input: 110 V AC/220 V AC, 50/60 Hz High-voltage DC input (3000 W AC power module): 240 V DC |
DC input: –48 V DC or –60 V DC
AC input: 110 V AC/220 V AC, 50/60 Hz High-voltage DC input (3000 W AC power module): 240 V DC |
|
Number of MPU slots
|
2
|
2
|
2
|
2
|
|
Number of power slots
|
4
|
6
|
4
|
6
|
|
Number of PoE power slots
|
0
|
0
|
0
|
0
|
|
Number of service board slots
|
4
|
8
|
10
|
12
|
|
Number of SFU slots
|
2
|
4
|
2
|
4
|
|
Number of system power slots
|
4
|
6
|
4
|
6
|
|
Redundant CMUs
|
Active-standby redundancy
|
Active-standby redundancy
|
Active-standby redundancy
|
Active-standby redundancy
|
|
Redundant Switch fabrics
|
N+1 hot standby
|
N+1 hot standby
|
Supports 1+1 protection.
|
N+1 hot standby
|
|
Redundant power supply
|
4(M+N)
|
6(M+N)
|
4(M+N)
|
6(M+N)
|
|
Redundant MPUs
|
The control unit works in hot standby mode, and the switching unit works in 1 + 1 load sharing mode.
|
The control unit works in hot standby mode, and the switching unit works in 1 + 1 load sharing mode.
|
The control unit works in hot standby mode, and the switching unit works in 1 + 1 load sharing mode.
|
The control unit works in hot standby mode, and the switching unit works in 1 + 1 load sharing mode.
|
|
Redundant fans
|
4 fan trays
|
4 fan trays
|
4 fan trays
|
5 fan trays
|
|
Automatic fan speed adjustment
|
Supported
|
Supported
|
Supported
|
Supported
|
|
Noise at normal temperature (acoustic power)
|
≤ 77.8
|
≤ 72
|
≤ 75.7
|
≤ 77.9
|
|
Airflow direction
|
Left-to-back airflow
|
Left-to-back airflow
|
Left-to-right back airflow
|
Left-to-back airflow
|
|
Long-term operating temperature
|
0°C to +45°C (32°F to 113°F) at an altitude of -60 m to +1800 m (-197 ft. to 5906 ft.)
|
0°C to +45°C (32°F to 113°F) at an altitude of -60 m to +1800 m (-197 ft. to 5906 ft.)
|
0°C to +45°C (32°F to 113°F) at an altitude of -60 m to +1800 m (-197 ft. to 5906 ft.)
|
0°C to +45°C (32°F to 113°F) at an altitude of -60 m to +1800 m (-197 ft. to 5906 ft.)
|
|
Storage temperature
|
-40°C to +70°C (-40°F to +158°F)
|
-40°C to +70°C (-40°F to +158°F)
|
-40°C to +70°C (-40°F to +158°F)
|
-40°C to +70°C (-40°F to +158°F)
|
|
Restriction on the operating temperature variation rate
|
When the altitude is 1800-4000 m (5906-13123 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
When the altitude is 1800-4000 m (5906-13123 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
When the altitude is 1800-4000 m (5906-13123 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
When the altitude is 1800-4000 m (5906-13123 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the
altitude increases by 220 m (722 ft.). |
|
Long-term operating relative humidity [RH]
|
5% to 95%, noncondensing
|
5% to 95%, noncondensing
|
5% to 95%, noncondensing
|
5% to 95%, noncondensing
|
|
Long-term operating altitude
|
-60 m to + 4000 m (-197 ft. to 13123 ft.)
|
-60 m to + 4000 m (-197 ft. to 13123 ft.)
|
-60 m to + 4000 m (-197 ft. to 13123 ft.)
|
-60 m to + 4000 m (-197 ft. to 13123 ft.)
|
|
Storage altitude
|
< 5000 m (16404 ft.)
|
< 5000 m (16404 ft.)
|
< 5000 m (16404 ft.)
|
< 5000 m (16404 ft.)
|
|
MTBF [year]
|
40.65
|
40.04
|
24.1
|
35.95
|
|
MTTR [h]
|
2
|
2
|
2
|
2
|
|
Availability
|
0.999998837
|
0.9999984
|
0.9999959
|
0.9999981
|
|
Maximum number of 100GE ports
|
32
|
64
|
80
|
96
|
|
Maximum number of 40GE ports
|
64
|
128
|
160
|
192
|
|
Maximum number of 25GE ports
|
NA
|
NA
|
NA
|
NA
|
|
Maximum number of 10GE ports
|
192
|
384
|
480
|
576
|
|
Maximum number of GE ports
|
192
|
384
|
480
|
576
|
|
Power supply surge protection
|
800 W AC power module, AC power port: ±4 kV in common mode and ±2 kV in differential mode
2200 W AC power module, AC power port: ±4 kV in common mode and ±2 kV in differential mode 3000 W AC power module, AC power port: ±6 kV in common mode and ±6 kV in differential mode 2200 W DC power module, DC power port: ±4 kV in common mode and ±2 kV in differential mode |
2200 W AC power module, AC power port: ±4 kV in common mode and ±2 kV in differential mode
3000 W AC power module, AC power port: ±6 kV in common mode and ±6 kV in differential mode 2200 W DC power module, DC power port: ±4 kV in common mode and ±2 kV in differential mode |
800 W AC power module, AC power port: ±4 kV in common mode and ±2 kV in differential mode
2200 W AC power module, AC power port: ±4 kV in common mode and ±2 kV in differential mode 3000 W AC power module, AC power port: ±6 kV in common mode and ±6 kV in differential mode 2200 W DC power module, DC power port: ±4 kV in common mode and ±2 kV in differential mode |
2200 W AC power module, AC power port: ±4 kV in common mode and ±2 kV in differential mode
3000 W AC power module, AC power port: ±6 kV in common mode and ±6 kV in differential mode 2200 W DC power module, DC power port: ±4 kV in common mode and ±2 kV in differential mode |
|
PoE
|
Not supported
|
Not supported
|
Not supported
|
Not supported
|
|
Relationship between PoE and system power modules
|
Only system power modules are involved.
|
Only system power modules are involved.
|
Only system power modules are involved.
|
Only system power modules are involved.
|
|
Maximum PoE output power per slot
|
NA
|
NA
|
NA
|
NA
|
|
Maximum number of PoE ports per slot
|
NA
|
NA
|
NA
|
NA
|
|
Maximum PoE output power [W]
|
NA
|
NA
|
NA
|
NA
|
|
Maximum power output capability (including the system power output and PoE power output) [W]
|
4*800 W AC: 3200 W (220 V input);
1600 W (110 V input) 4*2200 W AC: 8800 W (220 V input); 4400 W (110 V input) 4*3000 W AC: 8800 W (220 V input); 6000 W (110 V input) 4*2200 W DC: 8800 W |
6*2200 W AC: 8800 W (220 V input);
6600 W (110 V input) 6*3000 W AC: 8800 W (220 V input); 8800 W (110 V input) 6*2200 W DC: 8800 W |
4*800 W AC: 3200 W (220 V input);
1600 W (110 V input) 4*2200 W AC: 8800 W (220 V input); 4400 W (110 V input) 4*3000 W AC: 8800 W (220 V input); 6000 W (110 V input) 4*2200 W DC: 8800 W |
6*2200 W AC: 8800 W (220 V input);
6600 W (110 V input) 6*3000 W AC: 8800 W (220 V input); 8800 W (110 V input) 6*2200 W DC: 8800 W |



|
Part Number
|
Model
|
Description
|
||
|
2113563
|
LE2BN66EA000
|
N66E AC Assembly Rack(Four 16A Outputs,maximum 2500W per output,600X600X2200mm)
|
||
|
2113562
|
LE2BN66ED000
|
N66E DC Assembly Rack(Eight 60A outputs,maximum 2200W per output,600X600X2200mm)
|
||
|
2115869
|
ET1BS12704E0
|
S12700E-4 Assembly Chassis
|
||
|
2115870
|
ET1BS12708E0
|
S12700E-8 Assembly Chassis
|
||
|
2116009
|
ET1BS12712E1
|
S12700E-12 Assembly Chassis
|
||
|
03033ERF-002
|
LST7SFUMX100
|
S12700E switch fabric unit M(X1)
|
||
|
81401374
|
RTU-800G-S127E
|
S127E Series, 800G Capacity Right to Use License,Per Device
|
||
|
2122242
|
FAN-770A-B
|
Fan box(-5degC~55degC,48V,395W,2,Inside,VA)
|
||
|
Main Control Unit
|
|
|
||
|
03034DCK-001
|
LST7MPUE0001
|
S12700E main control unit E
|
||
|
03034HXL-001
|
LST7MPUEC000
|
S12700E main control unit EC
|
||
|
03033EMG-002
|
LST7SFUEX100
|
S12700E switch fabric unit E(X1)
|
||
|
03033ERD-002
|
LST7SFUHX100
|
S12700E switch fabric unit H(X1)
|
||
|
03030NWB
|
EH1D200CMU00
|
Centralized Monitoring Board
|
||
|
03034DHC-003
|
LST7G48TX6S0
|
48-port 100/1000BASE-T interface card (X6S,RJ45)
|
||
|
03034DGY-003
|
LST7G48TX6E0
|
48-port 100/1000BASE-T interface card (X6E,RJ45)
|
||
|
03033DMP-002
|
LST7G48SX6S0
|
48-port GE SFP interface card (X6S,SFP)
|
||
|
03033DMQ-002
|
LST7G48SX6E0
|
48-port GE SFP interface card (X6E,SFP)
|
||
|
03033DAN-002
|
LST7X24BX6S0
|
24-port 10GE SFP+ interface and 24-port GE SFP interface card (X6S,SFP+)
|
||
|
03033DAM-002
|
LST7X24BX6E0
|
24-port 10GE SFP+ interface and 24-port GE SFP interface card (X6E,SFP+)
|
||
|
03033BAD-002
|
LST7X48SX6S0
|
48-Port 10GE SFP+ interface card (X6S,SFP+)
|
||
|
03033BAH-002
|
LST7X48SX6E0
|
48-Port 10GE SFP+ interface card (X6E, SFP+)
|
||
|
03034DGS-003
|
LST7M24BX6E0
|
24-port 100M/1G/2.5G/5G/10G and 24-port 100M/1G interface card (X6E,RJ45)
|
||
|
03033LCW-001
|
LST7Y40SX6H0
|
40-port 25GE SFP28 interface card (X6H,SFP28)
|
||
|
03034DHG-002
|
LST7L12QX6E0
|
12-port 40GE QSFP+ inferface card (X6E,QSFP+)
|
||
|
03033DGE-002
|
LST7C06HX6S0
|
6-port 100GE QSFP28 interface card (X6S,QSFP28)
|
||
|
03033DGH-002
|
LST7C06HX6E0
|
6-port 100GE QSFP28 interface card (X6E, QSFP28)
|
||
|
03033FGU-002
|
LST7C24HX6E0
|
24-port 100GE QSFP28 interface card (X6E, QSFP28)
|
||
|
03033UGS-002
|
LST7C02BX6E0
|
2-port 100GE QSFP28 interface and 4-port 40GE QSFP28 inferface card (X6E,QSFP28)
|
||
|
2270117
|
W2PSD2200
|
2200W DC Power Module(Black)
|
||
|
02312FFP-001
|
PAC3KS54-CE
|
3000W AC Power Module(Black)
|
||
|
2131712
|
PAC3KS54-NE
|
3000W AC Power Module(Black)
|
||
|
2355418
|
IM1W24APD
|
AC Power Distribution Unit(Four 16A outputs,maximum 2500W per output,include power cable)
|
||
|
2355419
|
EH1M00PDBS01
|
DC Power Distribution Unit(Eight 60A Outputs,maximum 2200W per output,include power cable)
|
||
|
82402091
|
L-1AP-S127E
|
S127E Series, Wireless Access Controller AP Resource License-1AP
|
||
|
81401373
|
L-VxLAN-S127E
|
S127E Series, VxLAN License, Per Device
|
||
|
88037BNR
|
L-MLIC-S127E
|
S12700E Series Basic SW,Per Device
|
||
|
Optical Transceiver
|
|
|
||
|
02311BJJ
|
SFP-10G-iLR
|
Optical Transceiver,SFP+,9.8G,Single-mode Module(1310nm,1.4km,LC)
|
||
|
02311KNR
|
SFP-25G-SR
|
25GBase-SR Optical Transceiver-SFP28-25G Multi-mode(850nm,0.1km,LC)
|
||
|
02313URP
|
SFP-25G-SR
|
25GBase-SR Optical Transceiver-SFP28-25G Multi-mode(850nm,0.1km,LC)
|
||
|
02312LSE
|
SFP-25G-LR
|
25GBase-LR Optical Transceiver-SFP28-25G Single-mode(1310nm,10km,LC)
|
||
|
N1 License
|
|
|
||
|
88035WUB
|
N1-S127E-M-Lic
|
S127E Series Basic SW,Per Device
|
||
|
88062GKC
|
N1-S127E-M-SnS-3Y
|
S127E Series Basic SW,SnS,Per Device,3 Year
|
||
|
88035WCR
|
N1-S127E-F-Lic
|
N1-CloudCampus,Foundation,S127E Series,Per Device
|
||
|
88062GFL
|
N1-S127E-F-SnS-3Y
|
N1-CloudCampus,Foundation,S127E Series,SnS,Per Device,3 Year
(Annual fee validity period:3 years from" 90 days after PO signed")
|
||
|
88035WCS
|
N1-S127E-A-Lic
|
N1-CloudCampus,Advanced,S127E Series,Per Device
|
||
|
88062GFQ
|
N1-S127E-A-SnS-3Y
|
N1-CloudCampus,Advanced,S127E Series,SnS,Per Device,3 Year
|
||
|
88038HAQ
|
N1-S127E-MToF-Lic
|
N1-Upgrade-Basic Software to Foundation,S127E,Per Device
|
||
|
88062YGW
|
N1-S127E-MToF-SnS-3Y
|
N1-Upgrade-Basic Software to Foundation,S127E,SnS,Per Device,3 Year
|
||
|
88035WCT
|
N1-S127E-FToA-Lic
|
N1-Upgrade-Foundation to Advanced,S127E,Per Device
|
||
|
88062GYJ
|
N1-S127E-FToA-SnS-3Y
|
N1-Upgrade-Foundation to Advanced,S127E,SnS,Per Device,3 Year
|
||
|
88060FWR
|
N1-AC1.0-AM-15-SnS1Y
|
N1-CloudCampus,Access Management-AC1.0,15 Terminals,SnS,1Year
|
||
|
88060FVU
|
CI-X7MSwitch-U-SnS1Y
|
CampusInsight-Upgrade-Foundation to Advanced, X7 Series Modular Switch, SnS, Per Device, 1 Year
|
||