OptiX OSN 8800 T64 T32 T16 WDM/OTN Switching Platform New General Subrack, Optical Transport Network Equipment for 5G
$699.00 USD
- SupplierBoxintelecom (Yantai Boxin)
- MOQQuote on request
- Lead timeUsually 1–7 days
- WarehouseYantai / Hong Kong
Supplied by Boxintelecom — independent B2B distributor of original and compatible telecom spares. Ask for stock, lead time and MOQ within 24 hours.
Sourcing note from Boxintelecom
OptiX OSN 8800 T64 T32 T16 WDM/OTN Switching Platform New General Subrack, Optical Transport Network Equipment for 5G — Optical link family: SFP to QSFP28 transceivers, AOC and DAC cables for switch and router uplinks; state speed and reach. Item 10000031961722_custom, listed in Optical module.
Boxintelecom (Yantai Boxin International Trading Co., Ltd.) is an independent B2B distributor, not the OEM. Condition grade, quantity, MOQ, lead time and shipping are confirmed on the quotation; replies usually within 24 hours.
Brand names identify compatible or original equipment only; not affiliated with Huawei, Nokia, Ericsson, ZTE or FiberHome. RFQ: https://boxintelecom.com/pages/contact_us · WhatsApp +86-18554065950.
Product Details


|
Specifications
|
|
|
OptiX OSN 8800 T16
|
OptiX OSN 8800 T32a
|
OptiX OSN 8800 T64a
|
OptiX OSN 8800 UPS
|
||||||
|
Dimensions (mm)
|
|
|
498 (W) x 295 (D) x 450 (H)
|
498 (W) x 295 (D) x 900 (H)
|
498 (W) x 580 (D) x 900 (H)
|
442 (W) x 295 (D) x 397 (H)
|
||||||
|
Number of slots for service boards
|
|
|
16
|
32
|
64
|
DC: 16
|
||||||
|
|
|
|
|
|
|
AC: 15
|
||||||
|
Switch
|
Optical
|
|
1 to 20-degree ROADM
|
|
|
|
||||||
|
|
Electrical
|
|
1.6T ODUk(k=0, 1, 2, 2e, 3, 4, flex)
|
Enhanced subrack:
|
Enhanced subrack:
|
N/A
|
||||||
|
|
|
|
640G VC-4 and 20G VC-3/VC-12
|
3.2T ODUk(k=0, 1, 2, 2e, 3, 3e, 4, flex)
|
6.4T ODUk(k=0, 1, 2, 2e, 3, 4, flex)
|
|
||||||
|
|
|
|
800G Packet
|
1.28T VC-4 and 80G VC-3/VC-12
|
1.28T VC-4 and 80G VC-3/VC-12
|
|
||||||
|
|
|
|
|
1.6T Packet
|
General subrack:
|
|
||||||
|
|
|
|
|
General subrack:
|
2.56T ODUk(k=0, 1, 2, 2e, 3, flex)
|
|
||||||
|
|
|
|
|
2.56T ODUk(k=0, 1, 2, 2e, 3, 4, flex)
|
1.28T VC-4 and 80G VC-3/VC-12
|
|
||||||
|
|
|
|
|
1.28T VC-4 and 80G VC-3/VC-12
|
|
|
||||||
|
|
|
|
|
640G Packet
|
|
|
||||||
|
Wavelength (max)
|
|
|
DWDM: 96-channel, CWDM: 8-channel
|
|
|
DWDM: 96-ch
|
||||||
|
Center wavelength range
|
|
|
DWDM: 1529.16 nm to 1567.13 nm (extend C-band, ITU-T G.694.1)
|
|
|
DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1)
|
||||||
|
|
|
|
CWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2)
|
|
|
|
||||||
|
Max.rate per channel
|
|
|
400 Gbit/s (OTUC4)
|
|
|
|
||||||
|
Service types supported
|
|
|
SDH, SONET, Ethernet, SAN, OTN, Video
|
|
|
|
||||||
|
Line rate
|
|
|
2.5 Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/s, 200 Gbit/s, 400 Gbit/s
|
|
|
|
||||||
|
Supported pluggable optical modules
|
|
|
eSFP, SFP+, XFP, CFP, CFP2, QSFP28, QSFP+
|
|
|
|
||||||
|
Max.capacity per PID group
|
|
|
200 Gbit/s
|
|
|
N/A
|
||||||
|
Topology
|
|
|
Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, mesh
|
|
|
|
||||||
|
Redundancy and protection
|
Network level protection (OTN)
|
|
Optical line protection, intra-board 1+1 protection, client 1+1 protection, ODUk SNCP, tributary SNCP, SW SNCP, ODUk SPRing
protection, OWSP |
|
|
Optical line protection, intra-board 1+1 protection, client 1+1 protection, SW SNCP, OWSP
|
||||||
|
|
Network level protection (OCS)
|
|
Linear MSP, MSP ring, transoceanic MSP ring, SNCP, SNCTP
|
|
|
N/A
|
||||||
|
|
Network level protection (Ethernet and packet)
|
|
DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP and RSTP, Tunnel APS, VLAN SNCP
|
DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP and RSTP, Tunnel APS, VLAN SNCP
|
DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, STP and RSTP, VLAN SNCP
|
N/A
|
||||||
|
|
Equipment level protection
|
|
Power redundancy, fan redundancy, cross-connect board redundancy, system control and communication board redundancy, centralized
clock board redundancy, AUX board 1+1 redundancy |
|
|
Power redundancy, fan redundancy, system control and communication board redundancy
|
||||||
|
Optical power management
|
|
|
ALS, AGC, ALC, APE, IPA, OPA
|
|
|
|
||||||
|
Synchronization
|
|
|
Synchronous Ethernet clock
|
|
|
|
||||||
|
|
|
|
IEEE 1588v2
|
|
|
|
||||||
|
|
|
|
2 Mbit/s or 2 MHz (with the SSM function), ITU-T G.703-compliant external clock source
|
|
|
|
||||||
|
|
|
|
External time source (1PPS+TOD)
|
|
|
|
||||||
|
|
|
|
ITU-T G.8275.1/G.8273.2
|
|
|
|
||||||
|
Simple O&M
|
|
|
Optical Doctor System, Fiber Doctor System
|
|
|
|
||||||
|
ASON
|
|
|
An OTN network supports the Optical-Layer ASON and electrical-Layer ASON.
|
|
|
An OTN network supports the Optical-Layer ASON
|
||||||
|
|
|
|
An OCS network supports the SDH ASON feature.
|
|
|
|
||||||
|
|
|
|
NOTE:
|
|
|
|
||||||
|
|
|
|
The OptiX OSN 8800 T16 does not support the SDH ASON feature.
|
|
|
|
||||||
|
Submarine Features
|
|
|
Supports application of extended C band in submarine scenarios.
|
|
|
|
||||||
|
Nominal working voltage
|
|
|
-48 V DC/-60 V DC
|
-48 V DC/-60 V DC
|
-48 V DC/-60 V DC
|
DC Power:
|
||||||
|
|
|
|
Working voltage range:
|
Working voltage range:
|
Working voltage range:
|
Nominal working voltage: -48 V DC/-60 V DC
|
||||||
|
|
|
|
-48 V DC: -40 V to -57.6 V
|
-48 V DC: -40 V to -57.6 V
|
-48 V DC: -40 V to -57.6 V
|
Working voltage range:
|
||||||
|
|
|
|
-60 V DC: -48 V to -72 V
|
-60 V DC: -48 V to -72 V
|
-60 V DC: -48 V to -72 V
|
-48 V DC: -40 V to -57.6 V
|
||||||
|
|
|
|
|
|
|
-60 V DC: -48 V to -72 V
|
||||||
|
|
|
|
|
|
|
AC Power:
|
||||||
|
|
|
|
|
|
|
Nominal working voltage: 110V AC/220V AC
|
||||||
|
|
|
|
|
|
|
Working voltage range: 90 V AC to 290 V AC
|
||||||
|
Typical configuration power consumption
|
|
|
OTN subrack: 700W
|
Enhanced 8800 T32
|
Enhanced 8800 T64
|
N/A
|
||||||
|
|
|
|
OCS subrack: 821W
|
OTN subrack: 3300W
|
OTN subrack: 6000W
|
|
||||||
|
|
|
|
|
OCS subrack: 1791W
|
OCS subrack: 2135W
|
|
||||||
|
|
|
|
|
General 8800 T32
|
General 8800 T64
|
|
||||||
|
|
|
|
|
OTN subrack: 2000W
|
OTN subrack: 3700W
|
|
||||||
|
|
|
|
|
OCS subrack: 1282W
|
OCS subrack: 1748W
|
|
||||||
|
Maximum subrack power consumptionb
|
|
|
1800W
|
Enhanced 8800 T32: 4800W
|
Enhanced 8800 T64: 9600W
|
2400W
|
||||||
|
|
|
|
|
General 8800 T32: 4800W
|
General 8800 T64: 9600W
|
|
||||||
|
Operation environment
|
|
|
Subrack temperature:
|
|
|
|
||||||
|
|
|
|
Long-term operation: 5°C (41 °F) to 45°C (113 °F)
|
|
|
|
||||||
|
|
|
|
Short-term operation: -5°C (23 °F) to 55°C (131 °F)
|
|
|
|
||||||
|
|
|
|
Relative humidity:
|
|
|
|
||||||
|
|
|
|
Long-term operation: 5% to 85%
|
|
|
|
||||||
|
|
|
|
Short-term operation: 5% to 95%
|
|
|
|
||||||
|
Mean time to repair (MTTR)
|
|
|
4 hours
|
4 hours
|
4 hours
|
4 hours
|
||||||
|
Mean time between failures (MTBF)
|
|
|
62.80 years
|
60.40 years
|
58.68 years
|
51.64 years
|
||||||
|
a: There are two types of OptiX OSN 8800 T32 and 8800 T64 subracks: general and enhanced.Enhanced and general subracks are the same in appearance and technical specifications except for electrical cross-connect capacities and consumption.
|
|
|
|
|
|
|
||||||
|
b: The maximum subrack power consumption refers to the theoretical power consumption obtained when boards with the highest power consumption are installed in every slot on the subrack.
|
|
|
|
|
|
|
||||||
Contact Us
Yantai Boxin International Trade Co., Ltd.
Rock · Sales
Telegram / Phone
+86 186 6005 1788
Click the number to chat on WhatsApp or send an email. WeChat ID is the same as the phone number.