Model:
|
|
70112/24(701)
|
10212/24(102)
|
15224/48(152)
|
20224/48(202)
|
30224/48 (302)
|
|
Rated Power
|
|
700W
|
1000W
|
1500W
|
2000W
|
3000W
|
|
Peak Power(20ms)
|
|
2100VA
|
3000VA
|
4500VA
|
6000VA
|
9000VA
|
|
Start Motor
|
|
0.5HP
|
1HP
|
1.5HP
|
2HP
|
3HP
|
|
Battery Voltage
|
|
12/24VDC
|
12/24VDC
|
24/48VDC
|
24/48VDC
|
24/48VDC
|
|
Max AC charging current
|
|
0A~20A (Depending on the model, The maximum charging power is 1/4 of the rated power)
|
|
|
|
|
|
Built-in solar controller charging current (optional)
|
|
10A~60A (PWM or MPPT)
|
|
|
24/48V(PWM:10A~60A/MPPT:10A-100A)
|
|
|
Size(L*W*Hmm)
|
|
340x165x283
|
|
|
410x200x350
|
|
|
Packing Size(L*W*Hmm)
|
|
405x230x340(1pc)/475x415x350(2pc)
|
|
|
475x265x410
|
|
|
N.W.(kg)
|
|
9.5(1pc)
|
10.5(1pc)
|
11.5(1pc)
|
17
|
20.5
|
|
G.W.(kg)(Carton packaging)
|
|
11(1pc)
|
12(1pc)
|
13(1pc)
|
19
|
22.5
|
|
Installation Method
|
|
Tower
|
|
|
|
|
|
Input
|
DC Input Voltage Range
|
10.5-15VDC(Single battery voltage)
|
|
|
|
|
|
|
AC Input Voltage Range
|
73VAC~138VAC(110VAC)/83VAC~148VAC(120VAC)/145VAC~275VAC(220VAC)/155VAC~285VAC(230VAC)/165VAC~295VAC(240VAC)700W~7000W) 92VAC~128VAC(110VAC)/102VAC~138VAC(120VAC)/185VAC~255VAC(220VAC)/195VAC~265VAC(230VAC)/205VAC~275VAC(240VAC)(8KW~40KW)
|
|
|
|
|
|
|
AC Input Frequency Range
|
45Hz~55Hz(50Hz)/55Hz~65Hz(60Hz)
|
|
|
|
|
|
|
AC charging method
|
Three-stage (constant current, constant voltage, floating charge)
|
|
|
|
|
|
Output
|
Efficiency(Battery Mode)
|
≧85%
|
|
|
|
|
|
|
Output Voltage(Battery Mode)
|
110VAC±2%/120VAC±2%/220VAC±2%/230VAC±2%/240VAC±2%
|
|
|
|
|
|
|
Output Frequency(Battery Mode)
|
50Hz±0.5 or 60Hz±0.5
|
|
|
|
|
|
|
Output Wave(Battery Mode)
|
Pure Sine Wave
|
|
|
|
|
|
|
Efficiency(AC Mode)
|
≥99%
|
|
|
|
|
|
|
Output Voltage(AC Mode)
|
110VAC±10%/120VAC±10%/220VAC±10%/230VAC±10%/240VAC±10%(For models below or equal to 7kw); Follow Input (For models above 7Kw)
|
|
|
|
|
|
|
Output Frequency(AC Mode)
|
Follow input
|
|
|
|
|
|
|
Output waveform distortion(Battery Mode)
|
≤3%(Linear load)
|
|
|
|
|
|
|
No load loss(Battery Mode)
|
≤1% rated power
|
|
|
|
|
|
|
No load loss(AC Mode)
|
≤2% rated power( charger does not work in AC model)
|
|
|
|
|
|
|
No load loss(Energy saving Mode)
|
≤10W
|
|
|
|
|
|
Battery Type(selectable)
|
VRLA Battery
|
Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)
|
|
|
|
|
|
|
Customize battery
|
Charging and discharging parameters of different types of batteries can be customized according to user requirements(charging and discharging parameters of different types of batteries can be set through the operation panel)
|
|
|
|
|
|
Protection
|
Battery undervoltage alarm
|
Factory default: 11V(Single battery voltage)
|
|
|
|
|
|
|
Battery undervoltage protection
|
Factory default: 10.5V(Single battery voltage)
|
|
|
|
|
|
|
Battery overvoltage alarm
|
Factory default: 15V(Single battery voltage)
|
|
|
|
|
|
|
Battery overvoltage protection
|
Factory default: 17V(Single battery voltage)
|
|
|
|
|
|
|
Battery overvoltage recovery voltage
|
Factory default: 14.5V(Single battery voltage)
|
|
|
|
|
|
|
Overload power protection
|
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
|
|
|
|
|
|
|
Inverter output short circuit protection
|
Automatic protection (battery mode), circuit breaker or insurance (AC mode)
|
|
|
|
|
|
|
Temperature protection
|
>90°c(Shut down output)
|
|
|
|
|
|
Alarm
|
A
|
Normal working condition, buzzer has no alarm sound
|
|
|
|
|
|
|
B
|
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
|
|
|
|
|
|
|
C
|
When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
|
|
|
|
|
|
Inside Solar controller(Optional)
|
Charging Mode
|
PWM or MPPT
|
|
|
|
|
|
|
PV Input Voltage Range
|
PWM: 15V-44V(12V system); 30v-44V(24v system);60v-88V(48v system);120v-176V(96v system);。。。
MPPT:15v-120V(12v system);。。。
|
|
|
|
|
|
|
Max PV Input Voltage(Voc)(At the lowest temperature)
|
PWM:50V(12V/24Vsystem);100V(48V system);200V(96V system);400V(192Vsystem);500V(240Vsystem);750V(384V system)MPPT: 150V (12V/24V/48V system); 300V (96V system); 450V (192V system); 500V (240V system); 800V (384V system)
|
|
|
|
|
|
|
PV Array Maximum Power
|
12V system: 140W(10A)280W(20A/420W(30A)560W(40A)700W(50A/840W(60A/1120W(80A/1400W(100A)24V system: 280W(10A)560W(20A)/840W(30A/1120W(40A/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A)48V SSEM: 560W'10AV120W120AV'1680W30AV2240W40AV2800W50AV3360W'60AV4480WI80AV560OWY1 00AV6720WPWM 120AV5GKWN&1 2KWIMPT 100A200AI96V system: 5.6KW(50A)/11.2KW(100A);192V system: (PWM:11.2KW(50A)22.4KW(100A)/(MPPT:112KW(50A)/11.2*2KW(100A))240V SIEm: (PWM. 4KWS5OAV2BKWY100A) / (MPPT:14KW5OAV14*2KWY100A); 384V SIEM: (PWIM:224KW50AV448KWY100A) / (MPT224KW50AV22.4*2KW100A)
|
|
|
|
|
|
|
Standby loss
|
≤3W
|
|
|
|
|
|
|
Maximum conversion efficiency
|
>95%
|
|
|
|
|
|
Working Mode
|
|
Battery First/AC First/Saving Energy Mode
|
|
|
|
|
|
Transfer Time
|
|
≤4ms
|
|
|
|
|
|
Display
|
|
LCD
|
|
|
|
|
|
Thermal method
|
|
Cooling fan in intelligent control
|
|
|
|
|
|
Communication(Optional)
|
|
RS485/APP(WlFl monitoring or GPRS monitoring)
|
|
|
|
|
|
Environment
|
Operating temperature
|
-10 ℃ ~40 ℃
|
|
|
|
|
|
|
Storage temperature
|
-15℃~60℃
|
|
|
|
|
|
|
Noise
|
≤55dB
|
|
|
|
|
|
|
Elevation
|
2000m(More than derating)
|
|
|
|
|
|
|
Humidity
|
0%~95%,No condensation
|
|
|
|
|
|
|
Warranty
|
1 year
|
|
|
|
|