Specifications
|
|
|
OptiX OSN 8800 T16
|
OptiX OSN 8800 T32a
|
OptiX OSN 8800 T64a
|
OptiX OSN 8800 UPS
|
|
Dimensions (mm)
|
|
|
498 (W) x 295 (D) x 450 (H)
|
498 (W) x 295 (D) x 900 (H)
|
498 (W) x 580 (D) x 900 (H)
|
442 (W) x 295 (D) x 397 (H)
|
|
Number of slots for service boards
|
|
|
16
|
32
|
64
|
DC: 16
|
|
|
|
|
|
|
|
AC: 15
|
|
Switch
|
Optical
|
|
1 to 20-degree ROADM
|
|
|
|
|
|
Electrical
|
|
1.6T ODUk(k=0, 1, 2, 2e, 3, 4, flex)
|
Enhanced subrack:
|
Enhanced subrack:
|
N/A
|
|
|
|
|
640G VC-4 and 20G VC-3/VC-12
|
3.2T ODUk(k=0, 1, 2, 2e, 3, 3e, 4, flex)
|
6.4T ODUk(k=0, 1, 2, 2e, 3, 4, flex)
|
|
|
|
|
|
800G Packet
|
1.28T VC-4 and 80G VC-3/VC-12
|
1.28T VC-4 and 80G VC-3/VC-12
|
|
|
|
|
|
|
1.6T Packet
|
General subrack:
|
|
|
|
|
|
|
General subrack:
|
2.56T ODUk(k=0, 1, 2, 2e, 3, flex)
|
|
|
|
|
|
|
2.56T ODUk(k=0, 1, 2, 2e, 3, 4, flex)
|
1.28T VC-4 and 80G VC-3/VC-12
|
|
|
|
|
|
|
1.28T VC-4 and 80G VC-3/VC-12
|
|
|
|
|
|
|
|
640G Packet
|
|
|
|
Wavelength (max)
|
|
|
DWDM: 96-channel, CWDM: 8-channel
|
|
|
DWDM: 96-ch
|
|
Center wavelength range
|
|
|
DWDM: 1529.16 nm to 1567.13 nm (extend C-band, ITU-T G.694.1)
|
|
|
DWDM: 1529.16 nm to 1567.13 nm (extended C-band, ITU-T G.694.1)
|
|
|
|
|
CWDM: 1471 nm to 1611 nm (Band S+C+L, ITU-T G.694.2)
|
|
|
|
|
Max.rate per channel
|
|
|
400 Gbit/s (OTUC4)
|
|
|
|
|
Service types supported
|
|
|
SDH, SONET, Ethernet, SAN, OTN, Video
|
|
|
|
|
Line rate
|
|
|
2.5 Gbit/s, 10 Gbit/s, 40 Gbit/s, 100 Gbit/s, 200 Gbit/s, 400 Gbit/s
|
|
|
|
|
Supported pluggable optical modules
|
|
|
eSFP, SFP+, XFP, CFP, CFP2, QSFP28, QSFP+
|
|
|
|
|
Max.capacity per PID group
|
|
|
200 Gbit/s
|
|
|
N/A
|
|
Topology
|
|
|
Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, mesh
|
|
|
|
|
Redundancy and protection
|
Network level protection (OTN)
|
|
Optical line protection, intra-board 1+1 protection, client 1+1 protection, ODUk SNCP, tributary SNCP, SW SNCP, ODUk SPRing protection, OWSP
|
|
|
Optical line protection, intra-board 1+1 protection, client 1+1 protection, SW SNCP, OWSP
|
|
|
Network level protection (OCS)
|
|
Linear MSP, MSP ring, transoceanic MSP ring, SNCP, SNCTP
|
|
|
N/A
|
|
|
Network level protection (Ethernet and packet)
|
|
DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP and RSTP, Tunnel APS, VLAN SNCP
|
DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, PW APS, STP and RSTP, Tunnel APS, VLAN SNCP
|
DBPS, DLAG, ERPS, LAG, LPT, MC-LAG, MSTP, STP and RSTP, VLAN SNCP
|
N/A
|
|
|
Equipment level protection
|
|
Power redundancy, fan redundancy, cross-connect board redundancy, system control and communication board redundancy, centralized clock board redundancy, AUX board 1+1 redundancy
|
|
|
Power redundancy, fan redundancy, system control and communication board redundancy
|
|
Optical power management
|
|
|
ALS, AGC, ALC, APE, IPA, OPA
|
|
|
|
|
Synchronization
|
|
|
Synchronous Ethernet clock
|
|
|
|
|
|
|
|
IEEE 1588v2
|
|
|
|
|
|
|
|
2 Mbit/s or 2 MHz (with the SSM function), ITU-T G.703-compliant external clock source
|
|
|
|
|
|
|
|
External time source (1PPS+TOD)
|
|
|
|
|
|
|
|
ITU-T G.8275.1/G.8273.2
|
|
|
|
|
Simple O&M
|
|
|
Optical Doctor System, Fiber Doctor System
|
|
|
|
|
ASON
|
|
|
An OTN network supports the Optical-Layer ASON and electrical-Layer ASON.
|
|
|
An OTN network supports the Optical-Layer ASON
|
|
|
|
|
An OCS network supports the SDH ASON feature.
|
|
|
|
|
|
|
|
NOTE:
|
|
|
|
|
|
|
|
The OptiX OSN 8800 T16 does not support the SDH ASON feature.
|
|
|
|
|
Submarine Features
|
|
|
Supports application of extended C band in submarine scenarios.
|
|
|
|
|
Nominal working voltage
|
|
|
-48 V DC/-60 V DC
|
-48 V DC/-60 V DC
|
-48 V DC/-60 V DC
|
DC Power:
|
|
|
|
|
Working voltage range:
|
Working voltage range:
|
Working voltage range:
|
Nominal working voltage: -48 V DC/-60 V DC
|
|
|
|
|
-48 V DC: -40 V to -57.6 V
|
-48 V DC: -40 V to -57.6 V
|
-48 V DC: -40 V to -57.6 V
|
Working voltage range:
|
|
|
|
|
-60 V DC: -48 V to -72 V
|
-60 V DC: -48 V to -72 V
|
-60 V DC: -48 V to -72 V
|
-48 V DC: -40 V to -57.6 V
|
|
|
|
|
|
|
|
-60 V DC: -48 V to -72 V
|
|
|
|
|
|
|
|
AC Power:
|
|
|
|
|
|
|
|
Nominal working voltage: 110V AC/220V AC
|
|
|
|
|
|
|
|
Working voltage range: 90 V AC to 290 V AC
|
|
Typical configuration power consumption
|
|
|
OTN subrack: 700W
|
Enhanced 8800 T32
|
Enhanced 8800 T64
|
N/A
|
|
|
|
|
OCS subrack: 821W
|
OTN subrack: 3300W
|
OTN subrack: 6000W
|
|
|
|
|
|
|
OCS subrack: 1791W
|
OCS subrack: 2135W
|
|
|
|
|
|
|
General 8800 T32
|
General 8800 T64
|
|
|
|
|
|
|
OTN subrack: 2000W
|
OTN subrack: 3700W
|
|
|
|
|
|
|
OCS subrack: 1282W
|
OCS subrack: 1748W
|
|
|
Maximum subrack power consumptionb
|
|
|
1800W
|
Enhanced 8800 T32: 4800W
|
Enhanced 8800 T64: 9600W
|
2400W
|
|
|
|
|
|
General 8800 T32: 4800W
|
General 8800 T64: 9600W
|
|
|
Operation environment
|
|
|
Subrack temperature:
|
|
|
|
|
|
|
|
Long-term operation: 5°C (41 °F) to 45°C (113 °F)
|
|
|
|
|
|
|
|
Short-term operation: -5°C (23 °F) to 55°C (131 °F)
|
|
|
|
|
|
|
|
Relative humidity:
|
|
|
|
|
|
|
|
Long-term operation: 5% to 85%
|
|
|
|
|
|
|
|
Short-term operation: 5% to 95%
|
|
|
|
|
Mean time to repair (MTTR)
|
|
|
4 hours
|
4 hours
|
4 hours
|
4 hours
|
|
Mean time between failures (MTBF)
|
|
|
62.80 years
|
60.40 years
|
58.68 years
|
51.64 years
|
|
a: There are two types of OptiX OSN 8800 T32 and 8800 T64 subracks: general and enhanced.Enhanced and general subracks are the same in appearance and technical specifications except for electrical cross-connect capacities and consumption.
|
|
|
|
|
|
|
|
b: The maximum subrack power consumption refers to the theoretical power consumption obtained when boards with the highest power consumption are installed in every slot on the subrack.
|
|
|
|
|
|
|