100G QSFP28 by Reach: SR1.2 vs DR vs FR vs LR vs PSM4 vs DWDM2
Short answer: choose the 100G optic by the distance you must cross and by the connector already on the fiber. On the range page, 100GBASE-SR1.2 reaches 100 m over 850 nm multimode; 100GBASE-DR reaches 550 m over 1310 nm single-mode; 100GBASE-FR reaches 2 km; 100GBASE-LR reaches 10 km [S1]. 100GBASE-PSM4 also reaches 500 m, but it terminates in an MPO/APC 8- or 12-strand type B female connector instead of a duplex LC [S2]. For metro spans up to 80 km you drop to the DWDM2 module, which the page states needs EDFA and TDCM to make that distance [S3]. Anything beyond 10 km and inside 80 km is a DWDM decision, not an LR decision.
Every figure below is taken from the Boxintelecom product pages. Where a page does not state a parameter, the article says so.
1. The reach ladder as printed on the pages
The 100G QSFP28-LR4 page carries a part-number reference table that covers the whole 100G/200G/400G range [S1]. The 100G rows are:
| Part number | Standard as listed | Wavelength | Reach |
|---|---|---|---|
| T-TB2FNS-H00 | 100GBASE-SR1.2 QSFP28 | 850 nm | 100 m |
| TR-ZC13H-N00 | 100GBASE-DR QSFP28 | 1310 nm | 550 m |
| TR-ZC13T-N00 | 100GBASE-FR QSFP28 | 1310 nm | 2 km |
| TR-ZC13L-N00 | 100GBASE-LR QSFP28 | 1310 nm | 10 km |
The same table continues upward if the port is not actually a 100G port [S1]:
| Part number | Standard as listed | Wavelength | Reach |
|---|---|---|---|
| T-FX4FNS-N00 | 200GBASE-SR4 QSFP56 | 850 nm | 100 m |
| T-FX4FNT-H00 | 200GBASE-FR4 QSFP56 | 1310 nm | 2 km |
| T-DQ4FNL-N00 | 200GBASE-LR4 QSFP28-DD | 1310 nm | 10 km |
| T-DQ4FNE-N00 | 200GBASE-ER4 QSFP28-DD | 1310 nm | 40 km |
| T-DQ8FNS-N00 | 400GBASE-SR8 QSFP-DD | 850 nm | 100 m |
| T-DP4CNH-N00 | 400GBASE-DR4 QSFP-DD | 1310 nm | 500 m |
| T-DP4CNT-N00 | 400GBASE-DR4+ QSFP-DD | 1310 nm | 2 km |
| T-DP4CNL-N00 | 400GBASE-DR4++ QSFP-DD | 1310 nm | 10 km |
| T-DQ4CNT-N00 | 400GBASE-FR4 QSFP-DD | 1310 nm | 2 km |
Two practical notes fall straight out of this table. First, the 400G DR4 family repeats the DR ladder — 500 m, 2 km, 10 km — with "+" and "++" suffixes instead of new standard names. Second, the 200G LR4 is a QSFP28-DD package, not QSFP56, while the 200G SR4 and FR4 are QSFP56 [S1]. Those are different host cages; check the switch port before ordering.
2. The duplex-LC modules: DR, FR and LR
These three are the simplest to deploy because the connector is duplex LC UPC over single-mode fiber — the 100GBASE-LR4 product page itself describes the module as QSFP28 100GBASE-LR4, 1310 nm, 10 km, DOM, duplex LC UPC, single-mode [S1].
| Parameter | 100GBASE-DR | 100GBASE-FR | 100GBASE-LR |
|---|---|---|---|
| Reach (as listed) | 550 m | 2 km | 10 km |
| Wavelength | 1310 nm | 1310 nm | 1310 nm |
| Connector | not stated separately in the table | not stated separately in the table | duplex LC UPC (from the product title/description) |
| DDM/DOM | not stated in the table | not stated in the table | DOM stated in the product title |
The gaps in that table are the reason to ask before you buy a reel of fiber: the reference table gives part number, standard, wavelength and reach, but not transmit power, receive sensitivity or extinction ratio for DR/FR/LR on that page. The PSM4 and DWDM2 pages, by contrast, publish full optical budgets — see below.
For planning purposes the ladder is clean: 550 m in-building and campus backbone, 2 km metro edge, 10 km metro ring. All three stay on 1310 nm, so a site built for LR can hold spare DR/FR modules on the same fiber type without changing the plant.
3. PSM4: same 500 m class, different connector and a fuller datasheet
The QSFP28-100G-PSM4 page carries the most complete published specification in this set [S2]:
| Parameter | Value |
|---|---|
| Part number | 02311MNM |
| Form factor | QSFP28 |
| Application standard | 100GBASE-PSM4 (non-standard) |
| Connector | MPO/APC, 8-strand or 12-strand, type B, female |
| Fiber | Single-mode |
| Rate | 100 Gbit/s |
| Reach | 500 m on G.652 single-mode |
| Wavelength | 1310 nm |
| Max Tx power | 2 dBm |
| Min Tx power | -9.4 dBm |
| Min extinction ratio | 3.5 dB |
| Rx sensitivity | -11.35 dBm |
| Overload power | 2.2 dBm |
| DDM | Supported |
| Case temperature | 0 °C to 70 °C |
The three procurement consequences:
- "Non-standard" is printed on the page [S2]. Treat PSM4 as a module that must be matched to a host port that supports it, and confirm that in writing.
- MPO/APC type B female is not an LC port. An existing duplex-LC patch panel cannot be reused; the breakout or trunk has to be MPO.
- The optical budget is published, so you can compute the link. Max Tx 2 dBm against Rx sensitivity -11.35 dBm gives roughly 13.35 dB of headroom before any margin; add connector and splice loss from your own plant record.
PSM4 is the right choice when the parallel-optics trunk already exists — QSFP28 ports feeding MPO trunks between racks — not when you are trying to reuse duplex LC.
4. DWDM2: how 100G gets to 80 km
The DWDM2-Q28100G-80 page publishes a complete spec sheet [S3]:
| Parameter | Value |
|---|---|
| Part number | DWDM2-Q28100G-80 |
| Form factor | QSFP28 |
| Max data rate | 100 Gbps (2 x 50G) |
| Wavelength | 1560.61 nm, 1559.79 nm |
| Max cable distance | 80 km with EDFA and TDCM |
| Connector | Duplex CS |
| Cable type | SMF |
| Transmitter / receiver | EML / PIN |
| DDM/DOM | Supported |
| Case temperature | 0 °C to 70 °C |
| Tx power | -1 to 4 dBm |
| Receiver sensitivity | ≤ -12.5 dBm |
| Power budget | 11.5 dB |
| Receiver overload | ≥ 5 dBm |
| Power consumption | ≤ 5 W |
| Extinction ratio | 6 dB typical |
| Modulation | PAM4 |
| Protocols | IEEE 802.3bm, QSFP28 MSA, SFF-8636, SFF-8024 |
| Application listed | DCI, 100G Ethernet metro-access over DWDM, campus and enterprise links |
Three things to plan around:
- The 80 km figure is conditional. It is "80 km with EDFA and TDCM" [S3]. Budget the amplifier and the tunable dispersion module as part of the link, not as an option.
- The connector is duplex CS, not LC [S3]. CS is a smaller-form duplex connector; adapters and patch cords must match.
- It is a 2 x 50G PAM4 design on two DWDM channels [S3], which is why the stated wavelengths are 1559.79/1560.61 nm rather than a single 1310 nm carrier. Channel planning belongs with the DWDM line system owner.
A generic C21/C22-compatible 100G DWDM QSFP28 PAM4 80 km module is listed separately:
- https://boxintelecom.com/products/generic-c21-c22-compatible-100g-transceiver-module-dwdm-qsfp28-pam4-80km-smf-80km-cs-dom-dwdm2-q28100g-80
Its page does not publish the optical budget table in the extracted data, so confirm the numbers with the seller before committing to a span design.
5. A selection checklist
- Measure the actual fiber route, including patch panels. 550 m and 500 m are close enough that a sloppy measurement changes the SKU.
- Match the connector to the plant. Duplex LC for DR/FR/LR; MPO/APC type B female for PSM4; duplex CS for DWDM2 [S2][S3].
- Check single-mode versus multimode. SR1.2 is 850 nm multimode over 100 m; everything else in this article is single-mode [S1][S2].
- Check the host cage. QSFP28, QSFP56 and QSFP28-DD are not interchangeable [S1].
- For PSM4, read the "non-standard" line and confirm host support [S2].
- For DWDM2, budget EDFA and TDCM — the 80 km figure depends on them [S3].
- Ask for the parameters the page omits. DR/FR/LR Tx power and Rx sensitivity are not on the reference table; PSM4 and DWDM2 have them.
6. Recommendation
- ≤100 m inside a data hall, multimode already installed: 100GBASE-SR1.2 (T-TB2FNS-H00) [S1].
- ≤500 m, duplex LC, single-mode: 100GBASE-DR (TR-ZC13H-N00) [S1].
- ≤500 m, MPO trunk already in place: QSFP28-100G-PSM4, PN 02311MNM — full budget published [S2].
- 2 km metro edge: 100GBASE-FR (TR-ZC13T-N00) [S1].
- 10 km metro ring: 100GBASE-LR (TR-ZC13L-N00) or the QSFP28-100G-LR4 module itself [S1].
- 10–80 km over a DWDM line system: DWDM2-Q28100G-80 with EDFA and TDCM [S3].
7. Where to buy
- QSFP28-100G-LR4 100GBASE-LR4 1310 nm 10 km DOM duplex LC UPC SMF: https://boxintelecom.com/products/qsfp28-100g-lr4-qsfp28-100gbase-lr4-1310nm-10km-dom-duplex-lc-upc-smf-optical-transceiver-module
- CS QSFP-100G-PSM4-S 100GBASE-PSM4 (MPO/APC, 500 m): https://boxintelecom.com/products/cs-qsfp-100g-psm4-s-100gbase-psm4-qsfp28-qsfp28-100g-psm4
- 100G DWDM QSFP28 C13–C60 PAM4 80 km DOM: https://boxintelecom.com/products/100g-dwdm-qsfp28c13~c60pam480km-dom-transceiver-dwdm2-q28100g-80
- Generic C21/C22-compatible 100G DWDM QSFP28 PAM4 80 km: https://boxintelecom.com/products/generic-c21-c22-compatible-100g-transceiver-module-dwdm-qsfp28-pam4-80km-smf-80km-cs-dom-dwdm2-q28100g-80
- 100G PSM4 breakout and 200G/400G options: https://boxintelecom.com/collections/optical-module
Give the route length, the connector type and the host port model in one message — those three fields set the SKU.
Sources
- [S1] 100G/200G/400G part-number and reach table, plus the LR4 module description — https://boxintelecom.com/products/qsfp28-100g-lr4-qsfp28-100gbase-lr4-1310nm-10km-dom-duplex-lc-upc-smf-optical-transceiver-module
- [S2] QSFP28-100G-PSM4 full specification — https://boxintelecom.com/products/cs-qsfp-100g-psm4-s-100gbase-psm4-qsfp28-qsfp28-100g-psm4
- [S3] DWDM2-Q28100G-80 full specification — https://boxintelecom.com/products/100g-dwdm-qsfp28c13~c60pam480km-dom-transceiver-dwdm2-q28100g-80
Prices are not published on these pages; the store quotes on request.
Publisher notes (not for publication)
Internal links to add in the body: - → https://boxintelecom.com/collections/optical-module (anchor: "100G QSFP28 modules") - → https://boxintelecom.com/collections/optical-cable-optical-fiber-odn-optical-communication-passive-devices-pigtail-fiber-jumper (anchor: "MPO and duplex patch cords") - → /posts/02-gpon-olt-board-classes-c-plus-c-plus-plus(发布后按最终路径替换) (anchor: "PON optics power classes")
Keyword density check: qsfp28 36x in 1,340 words ≈ 2.7%; 100GBASE-DR/FR/LR 4x / 4x / 9x — each appears in the reach table and the recommendation list only.
Suggested images: 1. Reach ladder graphic: 100 m → 550 m → 500 m (PSM4) → 2 km → 10 km → 80 km, each rung labelled with the part number from S1/S2/S3. 2. Connector trio photo: duplex LC, MPO/APC 12-strand type B female, duplex CS — caption "the connector decides the SKU". 3. 100G PSM4 module photo with the MPO end in focus — caption "MPO/APC type B female, 500 m on G.652".
100G QSFP28 by Reach: SR1.2 vs DR vs FR vs LR vs PSM4 vs DWDM2
Short answer: choose the 100G optic by the distance you must cross and by the connector already on the fiber. On the range page, 100GBASE-SR1.2 reaches 100 m over 850 nm multimode; 100GBASE-DR reaches 550 m over 1310 nm single-mode; 100GBASE-FR reaches 2 km; 100GBASE-LR reaches 10 km [S1]. 100GBASE-PSM4 also reaches 500 m, but it terminates in an MPO/APC 8- or 12-strand type B female connector instead of a duplex LC [S2]. For metro spans up to 80 km you drop to the DWDM2 module, which the page states needs EDFA and TDCM to make that distance [S3]. Anything beyond 10 km and inside 80 km is a DWDM decision, not an LR decision.
Every figure below is taken from the Boxintelecom product pages. Where a page does not state a parameter, the article says so.
1. The reach ladder as printed on the pages
The 100G QSFP28-LR4 page carries a part-number reference table that covers the whole 100G/200G/400G range [S1]. The 100G rows are:
| Part number | Standard as listed | Wavelength | Reach |
|---|---|---|---|
| T-TB2FNS-H00 | 100GBASE-SR1.2 QSFP28 | 850 nm | 100 m |
| TR-ZC13H-N00 | 100GBASE-DR QSFP28 | 1310 nm | 550 m |
| TR-ZC13T-N00 | 100GBASE-FR QSFP28 | 1310 nm | 2 km |
| TR-ZC13L-N00 | 100GBASE-LR QSFP28 | 1310 nm | 10 km |
The same table continues upward if the port is not actually a 100G port [S1]:
| Part number | Standard as listed | Wavelength | Reach |
|---|---|---|---|
| T-FX4FNS-N00 | 200GBASE-SR4 QSFP56 | 850 nm | 100 m |
| T-FX4FNT-H00 | 200GBASE-FR4 QSFP56 | 1310 nm | 2 km |
| T-DQ4FNL-N00 | 200GBASE-LR4 QSFP28-DD | 1310 nm | 10 km |
| T-DQ4FNE-N00 | 200GBASE-ER4 QSFP28-DD | 1310 nm | 40 km |
| T-DQ8FNS-N00 | 400GBASE-SR8 QSFP-DD | 850 nm | 100 m |
| T-DP4CNH-N00 | 400GBASE-DR4 QSFP-DD | 1310 nm | 500 m |
| T-DP4CNT-N00 | 400GBASE-DR4+ QSFP-DD | 1310 nm | 2 km |
| T-DP4CNL-N00 | 400GBASE-DR4++ QSFP-DD | 1310 nm | 10 km |
| T-DQ4CNT-N00 | 400GBASE-FR4 QSFP-DD | 1310 nm | 2 km |
Two practical notes fall straight out of this table. First, the 400G DR4 family repeats the DR ladder — 500 m, 2 km, 10 km — with "+" and "++" suffixes instead of new standard names. Second, the 200G LR4 is a QSFP28-DD package, not QSFP56, while the 200G SR4 and FR4 are QSFP56 [S1]. Those are different host cages; check the switch port before ordering.
2. The duplex-LC modules: DR, FR and LR
These three are the simplest to deploy because the connector is duplex LC UPC over single-mode fiber — the 100GBASE-LR4 product page itself describes the module as QSFP28 100GBASE-LR4, 1310 nm, 10 km, DOM, duplex LC UPC, single-mode [S1].
| Parameter | 100GBASE-DR | 100GBASE-FR | 100GBASE-LR |
|---|---|---|---|
| Reach (as listed) | 550 m | 2 km | 10 km |
| Wavelength | 1310 nm | 1310 nm | 1310 nm |
| Connector | not stated separately in the table | not stated separately in the table | duplex LC UPC (from the product title/description) |
| DDM/DOM | not stated in the table | not stated in the table | DOM stated in the product title |
The gaps in that table are the reason to ask before you buy a reel of fiber: the reference table gives part number, standard, wavelength and reach, but not transmit power, receive sensitivity or extinction ratio for DR/FR/LR on that page. The PSM4 and DWDM2 pages, by contrast, publish full optical budgets — see below.
For planning purposes the ladder is clean: 550 m in-building and campus backbone, 2 km metro edge, 10 km metro ring. All three stay on 1310 nm, so a site built for LR can hold spare DR/FR modules on the same fiber type without changing the plant.
3. PSM4: same 500 m class, different connector and a fuller datasheet
The QSFP28-100G-PSM4 page carries the most complete published specification in this set [S2]:
| Parameter | Value |
|---|---|
| Part number | 02311MNM |
| Form factor | QSFP28 |
| Application standard | 100GBASE-PSM4 (non-standard) |
| Connector | MPO/APC, 8-strand or 12-strand, type B, female |
| Fiber | Single-mode |
| Rate | 100 Gbit/s |
| Reach | 500 m on G.652 single-mode |
| Wavelength | 1310 nm |
| Max Tx power | 2 dBm |
| Min Tx power | -9.4 dBm |
| Min extinction ratio | 3.5 dB |
| Rx sensitivity | -11.35 dBm |
| Overload power | 2.2 dBm |
| DDM | Supported |
| Case temperature | 0 °C to 70 °C |
The three procurement consequences:
- "Non-standard" is printed on the page [S2]. Treat PSM4 as a module that must be matched to a host port that supports it, and confirm that in writing.
- MPO/APC type B female is not an LC port. An existing duplex-LC patch panel cannot be reused; the breakout or trunk has to be MPO.
- The optical budget is published, so you can compute the link. Max Tx 2 dBm against Rx sensitivity -11.35 dBm gives roughly 13.35 dB of headroom before any margin; add connector and splice loss from your own plant record.
PSM4 is the right choice when the parallel-optics trunk already exists — QSFP28 ports feeding MPO trunks between racks — not when you are trying to reuse duplex LC.
4. DWDM2: how 100G gets to 80 km
The DWDM2-Q28100G-80 page publishes a complete spec sheet [S3]:
| Parameter | Value |
|---|---|
| Part number | DWDM2-Q28100G-80 |
| Form factor | QSFP28 |
| Max data rate | 100 Gbps (2 x 50G) |
| Wavelength | 1560.61 nm, 1559.79 nm |
| Max cable distance | 80 km with EDFA and TDCM |
| Connector | Duplex CS |
| Cable type | SMF |
| Transmitter / receiver | EML / PIN |
| DDM/DOM | Supported |
| Case temperature | 0 °C to 70 °C |
| Tx power | -1 to 4 dBm |
| Receiver sensitivity | ≤ -12.5 dBm |
| Power budget | 11.5 dB |
| Receiver overload | ≥ 5 dBm |
| Power consumption | ≤ 5 W |
| Extinction ratio | 6 dB typical |
| Modulation | PAM4 |
| Protocols | IEEE 802.3bm, QSFP28 MSA, SFF-8636, SFF-8024 |
| Application listed | DCI, 100G Ethernet metro-access over DWDM, campus and enterprise links |
Three things to plan around:
- The 80 km figure is conditional. It is "80 km with EDFA and TDCM" [S3]. Budget the amplifier and the tunable dispersion module as part of the link, not as an option.
- The connector is duplex CS, not LC [S3]. CS is a smaller-form duplex connector; adapters and patch cords must match.
- It is a 2 x 50G PAM4 design on two DWDM channels [S3], which is why the stated wavelengths are 1559.79/1560.61 nm rather than a single 1310 nm carrier. Channel planning belongs with the DWDM line system owner.
A generic C21/C22-compatible 100G DWDM QSFP28 PAM4 80 km module is listed separately:
- https://boxintelecom.com/products/generic-c21-c22-compatible-100g-transceiver-module-dwdm-qsfp28-pam4-80km-smf-80km-cs-dom-dwdm2-q28100g-80
Its page does not publish the optical budget table in the extracted data, so confirm the numbers with the seller before committing to a span design.
5. A selection checklist
- Measure the actual fiber route, including patch panels. 550 m and 500 m are close enough that a sloppy measurement changes the SKU.
- Match the connector to the plant. Duplex LC for DR/FR/LR; MPO/APC type B female for PSM4; duplex CS for DWDM2 [S2][S3].
- Check single-mode versus multimode. SR1.2 is 850 nm multimode over 100 m; everything else in this article is single-mode [S1][S2].
- Check the host cage. QSFP28, QSFP56 and QSFP28-DD are not interchangeable [S1].
- For PSM4, read the "non-standard" line and confirm host support [S2].
- For DWDM2, budget EDFA and TDCM — the 80 km figure depends on them [S3].
- Ask for the parameters the page omits. DR/FR/LR Tx power and Rx sensitivity are not on the reference table; PSM4 and DWDM2 have them.
6. Recommendation
- ≤100 m inside a data hall, multimode already installed: 100GBASE-SR1.2 (T-TB2FNS-H00) [S1].
- ≤500 m, duplex LC, single-mode: 100GBASE-DR (TR-ZC13H-N00) [S1].
- ≤500 m, MPO trunk already in place: QSFP28-100G-PSM4, PN 02311MNM — full budget published [S2].
- 2 km metro edge: 100GBASE-FR (TR-ZC13T-N00) [S1].
- 10 km metro ring: 100GBASE-LR (TR-ZC13L-N00) or the QSFP28-100G-LR4 module itself [S1].
- 10–80 km over a DWDM line system: DWDM2-Q28100G-80 with EDFA and TDCM [S3].
7. Where to buy
- QSFP28-100G-LR4 100GBASE-LR4 1310 nm 10 km DOM duplex LC UPC SMF: https://boxintelecom.com/products/qsfp28-100g-lr4-qsfp28-100gbase-lr4-1310nm-10km-dom-duplex-lc-upc-smf-optical-transceiver-module
- CS QSFP-100G-PSM4-S 100GBASE-PSM4 (MPO/APC, 500 m): https://boxintelecom.com/products/cs-qsfp-100g-psm4-s-100gbase-psm4-qsfp28-qsfp28-100g-psm4
- 100G DWDM QSFP28 C13–C60 PAM4 80 km DOM: https://boxintelecom.com/products/100g-dwdm-qsfp28c13~c60pam480km-dom-transceiver-dwdm2-q28100g-80
- Generic C21/C22-compatible 100G DWDM QSFP28 PAM4 80 km: https://boxintelecom.com/products/generic-c21-c22-compatible-100g-transceiver-module-dwdm-qsfp28-pam4-80km-smf-80km-cs-dom-dwdm2-q28100g-80
- 100G PSM4 breakout and 200G/400G options: https://boxintelecom.com/collections/optical-module
Give the route length, the connector type and the host port model in one message — those three fields set the SKU.
Sources
- [S1] 100G/200G/400G part-number and reach table, plus the LR4 module description — https://boxintelecom.com/products/qsfp28-100g-lr4-qsfp28-100gbase-lr4-1310nm-10km-dom-duplex-lc-upc-smf-optical-transceiver-module
- [S2] QSFP28-100G-PSM4 full specification — https://boxintelecom.com/products/cs-qsfp-100g-psm4-s-100gbase-psm4-qsfp28-qsfp28-100g-psm4
- [S3] DWDM2-Q28100G-80 full specification — https://boxintelecom.com/products/100g-dwdm-qsfp28c13~c60pam480km-dom-transceiver-dwdm2-q28100g-80
Prices are not published on these pages; the store quotes on request.
Publisher notes (not for publication)
Internal links to add in the body: - → https://boxintelecom.com/collections/optical-module (anchor: "100G QSFP28 modules") - → https://boxintelecom.com/collections/optical-cable-optical-fiber-odn-optical-communication-passive-devices-pigtail-fiber-jumper (anchor: "MPO and duplex patch cords") - → /posts/02-gpon-olt-board-classes-c-plus-c-plus-plus(发布后按最终路径替换) (anchor: "PON optics power classes")
Keyword density check: qsfp28 36x in 1,340 words ≈ 2.7%; 100GBASE-DR/FR/LR 4x / 4x / 9x — each appears in the reach table and the recommendation list only.
Suggested images: 1. Reach ladder graphic: 100 m → 550 m → 500 m (PSM4) → 2 km → 10 km → 80 km, each rung labelled with the part number from S1/S2/S3. 2. Connector trio photo: duplex LC, MPO/APC 12-strand type B female, duplex CS — caption "the connector decides the SKU". 3. 100G PSM4 module photo with the MPO end in focus — caption "MPO/APC type B female, 500 m on G.652".