Huawei S5735-L vs S5735-S: Which Access Switch Fits Your Site
Short answer: the letters after S5735 are not a generation marker, they are a power-and-cooling architecture. The S5735-L models documented on the product pages are fanless boxes with a built-in AC supply and, on the S5735-L48T4S-A1 page, explicitly "redundant power supply: not supported" [S1][S4]. The S5735-S models ship without a power module and take replaceable AC or DC supplies, including PoE+ and PoE++ modules, and they add 2 x 12GE stack ports [S3]. If the site needs PoE for cameras or APs, a hot-swappable supply, or a stack ring, the answer is S5735-S. If it is a quiet wiring closet with a handful of 10G uplinks, the S5735-L is the simpler buy.
All numbers below come from the Boxintelecom product pages. Where a page is silent, the text says so instead of filling the gap.
1. The concrete difference in one table
| Item | S5735-L8T4X-QA-V2 | S5735-L48T4S-A1 | S5735-S24T4XE-V2 |
|---|---|---|---|
| Fixed ports | 8 x 10/100/1000Base-T + 4 x 10GE SFP+ | Port count stated in the model name; page table gives thermal/mechanical data only | 24 x 10/100/1000Base-T + 4 x 10GE SFP+ + 2 x 12GE stack ports |
| Power supply | Built-in AC | Redundant power supply not supported | Without power module (modular) |
| Rated input | 100–240 V AC, 50/60 Hz | not stated in the table | not stated in the table |
| Max power consumption | 16.92 W | 50.4 W | not stated on page |
| Typical power consumption | not stated | 43.3 W | not stated on page |
| Cooling | Fanless, natural heat dissipation | Noise 48 dB(A) acoustic power, 36.2 dB(A) acoustic pressure | not stated on page |
| Height | 1 U | 1 U | not stated on page |
| Dimensions (H x W x D) | 43.6 x 250 x 180 mm | 43.6 x 442.0 x 220.0 mm (body); 90.0 x 550 x 360 mm packed | not stated on page |
| Operating temperature | -5 °C to +50 °C at 0–1800 m | -5 °C to +50 °C long-term, -5 °C to +55 °C short-term at 0–1800 m | not stated on page |
| MTBF | not stated | 56.7 years | not stated on page |
| Source | S1 | S4 | S3 |
The blank cells are real blanks on the pages, not omissions in this article. The S5735-S page publishes the port matrix and the module catalogue; it does not publish thermal or dimensional figures.
2. What the S5735-L actually is
2.1 A fanless, sealed box
The S5735-L8T4X-QA-V2 page lists fanless operation and natural heat dissipation, a maximum power draw of 16.92 W, and an operating window of -5 °C to +50 °C up to 1,800 m, derating by 1 °C for every 220 m above that [S1]. Storage is rated -40 °C to +70 °C and humidity 5% to 95% non-condensing [S1]. For a classroom, a small office or a retail back room, that combination means no fan filter to clean and no airflow to design.
The same page lists surge protection of ±7 kV common mode on service ports and ±6 kV differential / ±6 kV common mode on the power port [S1]. That is the kind of number you quote when the switch sits in a cabinet fed by an unshielded riser.
2.2 No redundant supply
The S5735-L48T4S-A1 page states, in the specification table, "Redundant power supply: Not supported" [S4]. It also publishes an availability figure above 0.99999, an MTBF of 56.7 years and an MTTR of 2 hours [S4]. Read those two rows together: the platform is designed to be reliable, but it is not designed to survive a power supply failure without downtime. If the site has a single-feed cabinet and a maintenance window long enough to swap a switch, that is an acceptable trade. If not, this is the row that disqualifies the model.
2.3 A second L variant with a very different power profile
The S5735-L8P2T4X-A-V2 page describes a different animal: 8 x 10GE electric ports, 2 x 10GE SFP+, 4 x 1GE electric, 2 x AC power supplies and 4 fan boxes with port-side blowing, a switching capacity up to 2.56 Tbps and a forwarding rate up to 1440 Mpps, 64K MAC addresses, 16K IPv4 routes, 6K IPv6 routes, 9 KB jumbo frames and 4,094 VLAN IDs, at 40 W typical and 60 W maximum with an MTBF above 200,000 hours [S2]. Note that this page states two AC supplies and four fan boxes — a cooled, redundant design — while the L8T4X-QA-V2 page states fanless with built-in AC [S1][S2]. The two "L" pages describe genuinely different hardware, so quote the exact model code, not just "S5735-L".
3. What the S5735-S actually is
The S5735-S page is a family sheet [S3]. It lists six chassis in one table:
- S5735-S24T4XE-V2 — 24 x GE, 4 x 10GE SFP+, 2 x 12GE stack, without power module
- S5735-S24P4XE-V2 — same plus PoE+
- S5735-S24U4XE-V2 — same plus PoE++
- S5735-S48T4XE-V2 — 48 x GE, 4 x 10GE SFP+, 2 x 12GE stack
- S5735-S48P4XE-V2 — same plus PoE+
- S5735-S48U4XE-V2 — same plus PoE++
The power module catalogue on the same page is the part that matters for budgeting [S3]:
| Module | Rating |
|---|---|
| PAC180S12-CN | 180 W AC |
| PAC600S12-PB | 600 W AC and 240 V DC |
| PDC1K2S12-CE | 1200 W DC |
| PAC600S56-EB | 600 W AC PoE |
| PAC1000S56-EB | 1000 W AC PoE |
| PDC1000S56-EB | 1000 W DC PoE |
Two consequences follow directly. First, "without power module" means the switch is not usable out of the box — the PSU is a separate line item on every S-model order. Second, the PoE models need a PoE-rated module, not the 180 W base module, once the port load is real.
The page also lists the licence SKUs (N1-S57S-M-Lic, N1-S57S-F-Lic, N1-S57S-A-Lite-Lic and their SnS variants) [S3]. Those are software items, not hardware, and they belong on the same purchase order or the switch arrives with base functionality only.
4. Decision rules that survive an audit
- Ask for the exact model code. "S5735-L" covers both a fanless 16.92 W box and a 60 W unit with two supplies and four fans [S1][S2]. Model code or nothing.
- Count the power modules on S models. Each S5735-S chassis is listed "without power module" [S3]; a quote that omits the PSU is incomplete.
- Match the PoE module to the PoE class. PoE+ and PoE++ chassis exist in the S family [S3], and the PoE-rated modules are separately listed [S3].
- Check the stack requirement. S5735-S carries 2 x 12GE stack ports [S3]; the L pages in this set do not list stack ports.
- Check the temperature window against the room. L8T4X-QA-V2 and L48T4S-A1 are both -5 °C to +50 °C at 0–1800 m, with the L48T4S-A1 allowing -5 °C to +55 °C short-term [S1][S4].
- Check the noise requirement. The L48T4S-A1 page publishes 48 dB(A) acoustic power and 36.2 dB(A) acoustic pressure [S4]; the L8T4X-QA-V2 page states fanless [S1]. If the switch goes in a room people sit in, that difference decides the model.
5. Recommendation
- Quiet closet, 8 copper ports, 4 x 10G uplinks, no PoE: S5735-L8T4X-QA-V2 — fanless, 16.92 W maximum, built-in AC [S1].
- 48-port access with no redundancy requirement: S5735-L48T4S-A1, but plan the maintenance window because redundant supply is not supported [S4].
- PoE for cameras or access points: S5735-S24P4XE-V2 or S48P4XE-V2 with a PAC600S56-EB / PAC1000S56-EB PoE module [S3].
- Stacked closet with 10G uplinks and a hot-swap supply: S5735-S24T4XE-V2 with the PAC600S12-PB module [S3].
- Any bid that cannot state the PSU model and the licence SKU: treat it as incomplete, not as a discount.
6. Where to buy
- S5735-L8T4X-QA-V2 (8 x GE + 4 x 10GE SFP+, fanless, built-in AC): https://boxintelecom.com/products/cloudengine-s5700-series-switches-s5735-l8t4x-qa-v2-98012073-8*10-100-1000base-t-ports-ethernet-enterprise-switch
- S5735-L8P2T4X-A-V2 (8 x 10GE + 2 x 10GE SFP+ + 4 x 1GE, dual AC, 2.56 Tbps): https://boxintelecom.com/products/cloudengine-series-s5735-l8p2t4x-a-v2-98011991-1000base-enterprise
- S5735-L48T4S-A1 (48-port, 43.6 x 442 x 220 mm, 50.4 W max): https://boxintelecom.com/products/cloudengine-series-s5735-l48t4s-a1-98011334-1000base-enterprise
- S5735-S24T4XE-V2 family sheet with power modules and licences: https://boxintelecom.com/products/cloudengine-series-s5735-s24t4xe-v2-98012016-1000base-s5735-s24t4x
- S5735-L1 PoE model, S5735-L24P4S-A1: https://boxintelecom.com/products/best-price-s5735-l1series-410-100-1000base-t-4ge-sfp-ports-poe-ac-power-s5735-l24p4s-a1
Put the model code, the PSU module and the licence in one RFQ; the store replies within 24 hours.
Sources
- [S1] S5735-L8T4X-QA-V2 specification table — https://boxintelecom.com/products/cloudengine-s5700-series-switches-s5735-l8t4x-qa-v2-98012073-8*10-100-1000base-t-ports-ethernet-enterprise-switch
- [S2] S5735-L8P2T4X-A-V2 specification table — https://boxintelecom.com/products/cloudengine-series-s5735-l8p2t4x-a-v2-98011991-1000base-enterprise
- [S3] S5735-S series port matrix, power modules and licences — https://boxintelecom.com/products/cloudengine-series-s5735-s24t4xe-v2-98012016-1000base-s5735-s24t4x
- [S4] S5735-L48T4S-A1 thermal and mechanical table — https://boxintelecom.com/products/cloudengine-series-s5735-l48t4s-a1-98011334-1000base-enterprise
Prices are not published on these pages; the store quotes by request.
Publisher notes (not for publication)
Internal links to add in the body: - → https://boxintelecom.com/collections/data-communication-products (anchor: "data communication switches") - → /posts/04-100g-qsfp28-reach-selection(发布后按最终路径替换) (anchor: "choosing 10G/100G uplink optics") - → https://boxintelecom.com/collections/switching-power-supply-power-module (anchor: "switch power modules")
Keyword density check: s5735-l 30x, s5735-s 23x in 1,334 words ≈ 2.2% / 1.7%. Both are model codes, used as nouns; no keyword block paragraphs.
Suggested images: 1. Rear view of the S5735-S chassis showing the empty power-module bay — caption "S5735-S ships without a power module". 2. Fanless S5735-L8T4X-QA-V2 top view with the 4 x 10GE SFP+ cages highlighted — caption "16.92 W maximum, natural heat dissipation". 3. Comparison graphic of acoustic numbers: 48 dB(A) / 36.2 dB(A) versus fanless — caption with the S4 figures.
Huawei S5735-L vs S5735-S: Which Access Switch Fits Your Site
Short answer: the letters after S5735 are not a generation marker, they are a power-and-cooling architecture. The S5735-L models documented on the product pages are fanless boxes with a built-in AC supply and, on the S5735-L48T4S-A1 page, explicitly "redundant power supply: not supported" [S1][S4]. The S5735-S models ship without a power module and take replaceable AC or DC supplies, including PoE+ and PoE++ modules, and they add 2 x 12GE stack ports [S3]. If the site needs PoE for cameras or APs, a hot-swappable supply, or a stack ring, the answer is S5735-S. If it is a quiet wiring closet with a handful of 10G uplinks, the S5735-L is the simpler buy.
All numbers below come from the Boxintelecom product pages. Where a page is silent, the text says so instead of filling the gap.
1. The concrete difference in one table
| Item | S5735-L8T4X-QA-V2 | S5735-L48T4S-A1 | S5735-S24T4XE-V2 |
|---|---|---|---|
| Fixed ports | 8 x 10/100/1000Base-T + 4 x 10GE SFP+ | Port count stated in the model name; page table gives thermal/mechanical data only | 24 x 10/100/1000Base-T + 4 x 10GE SFP+ + 2 x 12GE stack ports |
| Power supply | Built-in AC | Redundant power supply not supported | Without power module (modular) |
| Rated input | 100–240 V AC, 50/60 Hz | not stated in the table | not stated in the table |
| Max power consumption | 16.92 W | 50.4 W | not stated on page |
| Typical power consumption | not stated | 43.3 W | not stated on page |
| Cooling | Fanless, natural heat dissipation | Noise 48 dB(A) acoustic power, 36.2 dB(A) acoustic pressure | not stated on page |
| Height | 1 U | 1 U | not stated on page |
| Dimensions (H x W x D) | 43.6 x 250 x 180 mm | 43.6 x 442.0 x 220.0 mm (body); 90.0 x 550 x 360 mm packed | not stated on page |
| Operating temperature | -5 °C to +50 °C at 0–1800 m | -5 °C to +50 °C long-term, -5 °C to +55 °C short-term at 0–1800 m | not stated on page |
| MTBF | not stated | 56.7 years | not stated on page |
| Source | S1 | S4 | S3 |
The blank cells are real blanks on the pages, not omissions in this article. The S5735-S page publishes the port matrix and the module catalogue; it does not publish thermal or dimensional figures.
2. What the S5735-L actually is
2.1 A fanless, sealed box
The S5735-L8T4X-QA-V2 page lists fanless operation and natural heat dissipation, a maximum power draw of 16.92 W, and an operating window of -5 °C to +50 °C up to 1,800 m, derating by 1 °C for every 220 m above that [S1]. Storage is rated -40 °C to +70 °C and humidity 5% to 95% non-condensing [S1]. For a classroom, a small office or a retail back room, that combination means no fan filter to clean and no airflow to design.
The same page lists surge protection of ±7 kV common mode on service ports and ±6 kV differential / ±6 kV common mode on the power port [S1]. That is the kind of number you quote when the switch sits in a cabinet fed by an unshielded riser.
2.2 No redundant supply
The S5735-L48T4S-A1 page states, in the specification table, "Redundant power supply: Not supported" [S4]. It also publishes an availability figure above 0.99999, an MTBF of 56.7 years and an MTTR of 2 hours [S4]. Read those two rows together: the platform is designed to be reliable, but it is not designed to survive a power supply failure without downtime. If the site has a single-feed cabinet and a maintenance window long enough to swap a switch, that is an acceptable trade. If not, this is the row that disqualifies the model.
2.3 A second L variant with a very different power profile
The S5735-L8P2T4X-A-V2 page describes a different animal: 8 x 10GE electric ports, 2 x 10GE SFP+, 4 x 1GE electric, 2 x AC power supplies and 4 fan boxes with port-side blowing, a switching capacity up to 2.56 Tbps and a forwarding rate up to 1440 Mpps, 64K MAC addresses, 16K IPv4 routes, 6K IPv6 routes, 9 KB jumbo frames and 4,094 VLAN IDs, at 40 W typical and 60 W maximum with an MTBF above 200,000 hours [S2]. Note that this page states two AC supplies and four fan boxes — a cooled, redundant design — while the L8T4X-QA-V2 page states fanless with built-in AC [S1][S2]. The two "L" pages describe genuinely different hardware, so quote the exact model code, not just "S5735-L".
3. What the S5735-S actually is
The S5735-S page is a family sheet [S3]. It lists six chassis in one table:
- S5735-S24T4XE-V2 — 24 x GE, 4 x 10GE SFP+, 2 x 12GE stack, without power module
- S5735-S24P4XE-V2 — same plus PoE+
- S5735-S24U4XE-V2 — same plus PoE++
- S5735-S48T4XE-V2 — 48 x GE, 4 x 10GE SFP+, 2 x 12GE stack
- S5735-S48P4XE-V2 — same plus PoE+
- S5735-S48U4XE-V2 — same plus PoE++
The power module catalogue on the same page is the part that matters for budgeting [S3]:
| Module | Rating |
|---|---|
| PAC180S12-CN | 180 W AC |
| PAC600S12-PB | 600 W AC and 240 V DC |
| PDC1K2S12-CE | 1200 W DC |
| PAC600S56-EB | 600 W AC PoE |
| PAC1000S56-EB | 1000 W AC PoE |
| PDC1000S56-EB | 1000 W DC PoE |
Two consequences follow directly. First, "without power module" means the switch is not usable out of the box — the PSU is a separate line item on every S-model order. Second, the PoE models need a PoE-rated module, not the 180 W base module, once the port load is real.
The page also lists the licence SKUs (N1-S57S-M-Lic, N1-S57S-F-Lic, N1-S57S-A-Lite-Lic and their SnS variants) [S3]. Those are software items, not hardware, and they belong on the same purchase order or the switch arrives with base functionality only.
4. Decision rules that survive an audit
- Ask for the exact model code. "S5735-L" covers both a fanless 16.92 W box and a 60 W unit with two supplies and four fans [S1][S2]. Model code or nothing.
- Count the power modules on S models. Each S5735-S chassis is listed "without power module" [S3]; a quote that omits the PSU is incomplete.
- Match the PoE module to the PoE class. PoE+ and PoE++ chassis exist in the S family [S3], and the PoE-rated modules are separately listed [S3].
- Check the stack requirement. S5735-S carries 2 x 12GE stack ports [S3]; the L pages in this set do not list stack ports.
- Check the temperature window against the room. L8T4X-QA-V2 and L48T4S-A1 are both -5 °C to +50 °C at 0–1800 m, with the L48T4S-A1 allowing -5 °C to +55 °C short-term [S1][S4].
- Check the noise requirement. The L48T4S-A1 page publishes 48 dB(A) acoustic power and 36.2 dB(A) acoustic pressure [S4]; the L8T4X-QA-V2 page states fanless [S1]. If the switch goes in a room people sit in, that difference decides the model.
5. Recommendation
- Quiet closet, 8 copper ports, 4 x 10G uplinks, no PoE: S5735-L8T4X-QA-V2 — fanless, 16.92 W maximum, built-in AC [S1].
- 48-port access with no redundancy requirement: S5735-L48T4S-A1, but plan the maintenance window because redundant supply is not supported [S4].
- PoE for cameras or access points: S5735-S24P4XE-V2 or S48P4XE-V2 with a PAC600S56-EB / PAC1000S56-EB PoE module [S3].
- Stacked closet with 10G uplinks and a hot-swap supply: S5735-S24T4XE-V2 with the PAC600S12-PB module [S3].
- Any bid that cannot state the PSU model and the licence SKU: treat it as incomplete, not as a discount.
6. Where to buy
- S5735-L8T4X-QA-V2 (8 x GE + 4 x 10GE SFP+, fanless, built-in AC): https://boxintelecom.com/products/cloudengine-s5700-series-switches-s5735-l8t4x-qa-v2-98012073-8*10-100-1000base-t-ports-ethernet-enterprise-switch
- S5735-L8P2T4X-A-V2 (8 x 10GE + 2 x 10GE SFP+ + 4 x 1GE, dual AC, 2.56 Tbps): https://boxintelecom.com/products/cloudengine-series-s5735-l8p2t4x-a-v2-98011991-1000base-enterprise
- S5735-L48T4S-A1 (48-port, 43.6 x 442 x 220 mm, 50.4 W max): https://boxintelecom.com/products/cloudengine-series-s5735-l48t4s-a1-98011334-1000base-enterprise
- S5735-S24T4XE-V2 family sheet with power modules and licences: https://boxintelecom.com/products/cloudengine-series-s5735-s24t4xe-v2-98012016-1000base-s5735-s24t4x
- S5735-L1 PoE model, S5735-L24P4S-A1: https://boxintelecom.com/products/best-price-s5735-l1series-410-100-1000base-t-4ge-sfp-ports-poe-ac-power-s5735-l24p4s-a1
Put the model code, the PSU module and the licence in one RFQ; the store replies within 24 hours.
Sources
- [S1] S5735-L8T4X-QA-V2 specification table — https://boxintelecom.com/products/cloudengine-s5700-series-switches-s5735-l8t4x-qa-v2-98012073-8*10-100-1000base-t-ports-ethernet-enterprise-switch
- [S2] S5735-L8P2T4X-A-V2 specification table — https://boxintelecom.com/products/cloudengine-series-s5735-l8p2t4x-a-v2-98011991-1000base-enterprise
- [S3] S5735-S series port matrix, power modules and licences — https://boxintelecom.com/products/cloudengine-series-s5735-s24t4xe-v2-98012016-1000base-s5735-s24t4x
- [S4] S5735-L48T4S-A1 thermal and mechanical table — https://boxintelecom.com/products/cloudengine-series-s5735-l48t4s-a1-98011334-1000base-enterprise
Prices are not published on these pages; the store quotes by request.
Publisher notes (not for publication)
Internal links to add in the body: - → https://boxintelecom.com/collections/data-communication-products (anchor: "data communication switches") - → /posts/04-100g-qsfp28-reach-selection(发布后按最终路径替换) (anchor: "choosing 10G/100G uplink optics") - → https://boxintelecom.com/collections/switching-power-supply-power-module (anchor: "switch power modules")
Keyword density check: s5735-l 30x, s5735-s 23x in 1,334 words ≈ 2.2% / 1.7%. Both are model codes, used as nouns; no keyword block paragraphs.
Suggested images: 1. Rear view of the S5735-S chassis showing the empty power-module bay — caption "S5735-S ships without a power module". 2. Fanless S5735-L8T4X-QA-V2 top view with the 4 x 10GE SFP+ cages highlighted — caption "16.92 W maximum, natural heat dissipation". 3. Comparison graphic of acoustic numbers: 48 dB(A) / 36.2 dB(A) versus fanless — caption with the S4 figures.