Fournisseur B2B d'équipements télécom — Demandez un devis aujourd'hui
Fournisseur B2B d'équipements télécom — Demandez un devis aujourd'hui
Équipements réseau 2G/3G/4G/5G — Nokia, Ericsson, Huawei, ZTE et plus
Équipements réseau 2G/3G/4G/5G — Nokia, Ericsson, Huawei, ZTE et plus
Worldwide Shipping
Sea freight, land transport, air freight
1 / 5

Jiangnan Cable National Standard Copper Core RVV/YC/RVVP Soft Power Cord 2-30 Core 0.5-6 Flat Flame retardant and Wear resistant

CFA1,129 XOF
Couleur
Size
Description du produit

 

Rated voltage 0.6/1kV cross-linked polyethylene insulated power cable

Usage characteristics

The maximum allowable long-term working temperature for cable conductors is 90℃;

 

The maximum temperature of the cable conductor during a short circuit (maximum duration not exceeding 5 seconds) shall not exceed 250℃;

 

The ambient temperature during cable laying should not be lower than 0℃;

 

The bending radius of the cable shall not be less than 15 times the outer diameter of the cable;

 

The model and name of the cable

Model Name Applicable scope
YJV Copper core cross-linked polyethylene insulated polyvinyl chloride sheathed power cable Indoor, tunnel, cable trench and other places do not need to withstand mechanical external forces.Single core cables are not allowed to be laid in magnetic pipelines.
YJLV Aluminum core cross-linked polyethylene insulated polyvinyl chloride sheathed power cable Indoor, tunnel, cable trench and other places do not need to withstand mechanical external forces.Single core cables are not allowed to be laid in magnetic pipelines.
YJY Copper core cross-linked polyethylene insulated polyethylene sheathed power cable Indoor, tunnel, cable trench and other places do not need to withstand mechanical external forces.Single core cables are not allowed to be laid in magnetic pipelines.
YJLY Aluminum core cross-linked polyethylene insulated polyethylene sheathed power cable Indoor, tunnel, cable trench and other places do not need to withstand mechanical external forces.Single core cables are not allowed to be laid in magnetic pipelines.
YJV22 Copper core cross-linked polyethylene insulated steel strip armored polyvinyl chloride sheathed power cable Indoor, tunnel, cable trench or underground laying places that need to withstand certain radial mechanical external forces.
YJLV22 Aluminum core cross-linked polyethylene insulated steel strip armored polyvinyl chloride sheathed power cable Indoor, tunnel, cable trench or underground laying places that need to withstand certain radial mechanical external forces.
YJV23 Copper core cross-linked polyethylene insulated steel strip armored polyethylene sheathed power cable Indoor, tunnel, cable trench or underground laying places that need to withstand certain radial mechanical external forces.
YJLV23 Aluminum core cross-linked polyethylene insulated steel strip armored polyethylene sheathed power cable Indoor, tunnel, cable trench or underground laying places that need to withstand certain radial mechanical external forces.
YJV32 Copper core cross-linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable Indoor, tunnel, cable trench, vertical shaft or buried laying, etc., can withstand a certain tensile force.
YJLV32 Aluminum core cross-linked polyethylene insulated fine steel wire armored polyvinyl chloride sheathed power cable Indoor, tunnel, cable trench, vertical shaft or buried laying, etc., can withstand a certain tensile force.
YJV33 Copper core cross-linked polyethylene insulated fine steel wire armored polyethylene sheathed power cable Indoor, tunnel, cable trench, vertical shaft or buried laying, etc., can withstand a certain tensile force.
YJLV33 Aluminum core cross-linked polyethylene insulated fine steel wire armored polyethylene sheathed power cable Indoor, tunnel, cable trench, vertical shaft or buried laying, etc., can withstand a certain tensile force.

 

 

 

Model

CORE

Nominal cross-section mm2

Copper Conductor

aluminum conductor

YJV   YJY

YJV62  YJV63

YJLV   YJLY

YJLV62  YJLV63

1

1.5~800

10~800

YJV   YJY

YJV22  YJV23

YJV32  YJV33

YJLV   YJLY

YJLV22  YJLV23

YJLV32  YJLV33

2

 

1.5~400

2.5~400

10~400

YJV   YJY

YJV22  YJV23

YJV32  YJV33

YJLV   YJLY

YJLV22  YJLV23

YJLV32  YJLV33

3

1.5~630

2.5~630

10~630

YJV   YJY

YJV22  YJV23

YJV32  YJV33

YJLV   YJLY

YJLV22  YJLV23

YJLV32  YJLV33

4

1.5~500

2.5~500

10~500

YJV   YJY

YJV22  YJV23

YJV32  YJV33

YJLV   YJLY

YJLV22  YJLV23

YJLV32  YJLV33

3+1

1.5~630

4~630

10~630

YJV   YJY

YJV22  YJV23

YJV32  YJV33

YJLV   YJLY

YJLV22  YJLV23

YJLV32  YJLV33

5

1.5~500

2.5~500

10~500

YJV   YJY

YJV22  YJV23

YJV32  YJV33

YJLV   YJLY

YJLV22  YJLV23

YJLV32  YJLV33

4+1

1.5~500

4~500

10~500

YJV   YJY

YJV22  YJV23

YJV32  YJV33

YJLV   YJLY

YJLV22  YJLV23

YJLV32  YJLV33

3+2

1.5~500

4~500

10~500

 

Note: Single core armored cables are suitable for DC systems.If used in AC systems, non-magnetic materials should be used for armor or magnetic isolation measures.

 

 

Maximum DC resistance of conductor at 20℃

Nominal cross-section of conductor   mm2

Maximum DC resistance of conductor at 20 ℃ (Ω/km)

copper

aluminium

1

18.1

--

1.5

12.1

--

2.5

7.41

12.1

4

4.61

7.41

6

3.08

4.61

10

1.83

3.08

16

1.15

1.91

25

0.727

1.20

35

0.524

0.868

50

0.387

0.641

70

0.268

0.443

95

0.193

0.320

120

0.153

0.253

150

0.124

0.206

185

0.0991

0.164

240

0.0754

0.125

300

0.0601

0.100

400

0.0470

0.0778

500

0.0366

0.0605

630

0.0283

0.0469

800

0.0221

0.0367

Power frequency AC voltage test

testing voltage   3.5kV/5min

 

 

 

 

Operating conditions for cable laying

 

When laying in the air, when single core cables are laid in parallel, the center distance: 185mm2 or less is twice the cable diameter; 240mm2 and above are 90mm.

 

Surrounding air temperature: 30℃

 

Long term maximum operating temperature of conductor: 90℃

 

 

 

Direct buried laying

 

When a single core cable is laid without contact, the center distance of the cable is twice the diameter of the cable.

 

Soil temperature: 25℃.

 

The long-term maximum operating temperature of the conductor is 90℃.

 

Soil thermal resistance coefficient: 1.0℃.m/W.

 

Direct burial depth: 0.7m.

 

 

 

Contactez-nous

Yantai Boxin International Trade Co., Ltd.

Huijiang · Ventes

WhatsApp / WeChat / Phone

+86 185 5406 5950

[email protected]

Anna · Ventes

WhatsApp / WeChat / Phone

+86 186 6382 8268

[email protected]

Cliquez sur le numéro pour discuter sur WhatsApp ou envoyez un e-mail. L'identifiant WeChat est le même que le numéro.

Jiangnan Cable National Standard Copper Core RVV/YC/RVVP Soft Power Cord 2-30 Core 0.5-6 F Jiangnan Cable National Standard Copper Core RVV/YC/RVVP Soft Power Cord 2-30 Core 0.5-6 F Jiangnan Cable National Standard Copper Core RVV/YC/RVVP Soft Power Cord 2-30 Core 0.5-6 F Jiangnan Cable National Standard Copper Core RVV/YC/RVVP Soft Power Cord 2-30 Core 0.5-6 F Jiangnan Cable National Standard Copper Core RVV/YC/RVVP Soft Power Cord 2-30 Core 0.5-6 F

Spécifications techniques

Fréquences et bandes

Supports 2G/3G/4G/5G frequency bands. Detailed band specifications depend on the specific model and configuration. Contact our sales team for the exact band coverage of your target market.

Interfaces et connecteurs

Standard telecom interfaces including optical ports, RF connectors, Ethernet ports and power interfaces. Connector types and quantities vary by product model. Full interface specifications available in the product datasheet.

Alimentation et consommation

Operating voltage range, power consumption and power supply requirements differ by equipment type. Typical operating temperature range: -40°C to +55°C. Detailed power specifications provided on request.

Certifications et conformité

Products comply with CE, RoHS, FCC and ISO 9001 standards where applicable. Certification documents and test reports are available for verified B2B customers upon request.

Compatibilité et déploiement

Compatible with major telecom infrastructure vendors. Suitable for indoor and outdoor deployment scenarios including base stations, transmission nodes and optical distribution networks. Custom configurations available for large-scale projects.

Demander un devis en gros

Besoin de ce produit en volume ? Contactez notre équipe pour des prix B2B, la personnalisation et la livraison. Réponse sous 24 heures.

Vous aimerez aussi